RE: dialout minwait and curwait?

#76
From: Sascha Picchiantano
Date: Mon, 11 May 1998 00:00
17 lines
995 bytes
Hi Mike,

> >    dialout interface 60 callback
> >
>
> I assume you mean "dialout <dialout-name> minwait 60 callback" here.

Uhm.... yes :)

> I believe that you also need to set "dialout maxwait" to some number
> greater than the minwait setting, or else the minwait setting will not
> have any effect.  What is your maxwait set to?

That was it. I didn't have the maxwait set. Thanks!

Sascha