AES <siegman@stanford.edu> wrote in news:siegman-5AF1F3.09005231072010 @bmedcfsc-srv02.tufts.ad.tufts.edu: > OT question for any posters or readers of the exchange on emergency > power generators appended below: > > I have a 10 kW standard residential solar photovoltaic system on my roof > (no batteries or other added complexities). I understand that if PG&E > goes down it stops functioning, and more or less why this is. > > Suppose I acquired a small generator and had professionals install the > necessary (manual) switching to disconnect my house and the solar setup > from PG&E and connect them to the generator. > > Once this switch was thrown and the generator fired up, would the solar > system function normally while the generator was running? If so, what > size generator might be required? > > I don't understand your system, to begin with. If you have no batteries to store what the panels make, you have no power on days with no sun. Is that correct?? I've never seen a solar system without storage, before. What would you do for lighting at night when the power goes down. Both your systems would be dead, not just the solar. That doesn't make sense to me. I'd keep the panels loaded charging massive battery banks if I had that much money invested in solar panels. 10KW is a MASSIVE array! There'd be a serious 48 or 96 or 144VDC battery house on the property with a few KW of 115/230 inverters that would autoswitch the mains from the utility to the inverters when utility fails. You'd never even see the lights blink! With so much solar energy simply going to waste because you're NOT storing all its potential just leaving the panels cooking in the sun on the immediate load, then going dark when the sun gets low in the sky, that's a terrible waste of potential useful energy, unless you're selling it to the utility through a reversible meter, which I suspect you will tell us is what you're doing. There'd be no point in the investment, otherwise. I wouldn't buy a generator with so much available power for free. I'd build a battery house with some massive stationary batteries also used to power large electric fork lift trucks and quit selling it back to the utility for peanuts. 10KW for 6 hours a day, 60KWH on a good day in California is plenty to run a fairly good energy efficient home. If it proved to be enough, I'd simply tell PG&E to stuff it! 60 x 20 days (guessing an average in sunny California month) = 1200 KWH. With a little conservation and energy efficiency I'd be power company free! But, if you are determined to put in a genset that will power the house, a 20KW propane would be appropriate, I'd think. Automatic start and switchgear for it isn't a huge investment. It cranks when the power blinks, even if it doesn't fail, and puts the load on the genset until the power system settles, then shuts itself off after X minutes and puts you back on the grid. I like propane for two reasons. Natural gas would be great, but you live in an earthquake zone where natural gas disruptions are an issue as the fault line breaks the gas lines. A big propane tank isn't pretty....well, not until the neighborhood is in total darkness and you're house sticks out like a sore thumb with all the lights on half the night. Then, propane tanks are downright BEAUTIFUL! The propane company will automatically keep them topped up and you will do nothing to keep them topped up, unlike gasoline you'd be hauling yourself. Diesel is a great fuel IF YOU USE IT OFTEN. Diesel fuel grows black algae and is hygroscopic, collecting water right out of the vented air. When you need it most, if it's been sitting in a standby condition, it may not be ready for use loaded with algae that required constant maintenance. Propane can sit in a tank until your kids are grandparents and crank the genset immediately. It doesn't "go bad" like gasoline or diesel and if the gas lines downtown rupture and the neighborhood has no natural gas pressure, you STILL ARE RUNNING on propane. A 15-25KW propane genset with autostart and switchgear would be great for your system. Compared to 10KW in solar panels, it's downright cheap! Your electrical contractor can do a power use survey and recommend a suitable system. Mine is just a guess. Electrical Engineers don't, usually, bite and most are housebroken. I'd guess there are plenty of them at Stanford that have some knowledge of PRACTICAL systems that could plan it. If the EE department can be persuaded to make your electrical system a "student project", you may even get the Federal Government to fund it through the school. I used to teach electronics technicians in a technical college on a much lower level than Stanford. The Air Conditioning and Refridgeration School made a student project of our house and I ended up with a steal on 7 tons of overkill for the price of 2 tons, neatly installed by the students. Check the school. Plenty of grants going around. Make it say something about "Global Warming" and "Saving the Planet" and it's sure to be approved, even if it's a new toilet. -- iPhone 4 is to cellular technology what the Titanic is to cruise ships. Larry
Technical Details
Message-ID:
<Xns9DC740ED21BEnoonehomecom@74.209.131.13>Path:
arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!npeer03.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!post01.iad.highwinds-media.com!KNOLOGY.NET-a2kHrUvQQWlmc!not-for-mailReferences:
<osk0561hjli19tfrgtu12b80anh8i5dj4r@4ax.com> <Xns9DC38F616A32Anoonehomecom@74.209.131.13> <i2ratc$tt7$1@news.eternal-september.org> <slrni52s9n.3sf.dcferguson@akit-ferguson.com> <3723561um0afo49klm46v2hd0cftv2s02h@4ax.com> <WYg4o.45954$YX3.29653@newsfe18.iad> <higgy-3793A3.12250429072010@news.announcetech.com> <i2sntq$udo$1@news.eternal-september.org> <higgy-ABE0C1.23345229072010@news.announcetech.com> <i2ubtr$t96$2@news.eternal-september.org> <usm556dg9jo79qvdsk1d9ckdv37nolnrcp@4ax.com> <Xns9DC5C2F6F85CDnoonehomecom@74.209.131.13> <higgy-733304.22355230072010@news.announcetech.com> <siegman-5AF1F3.09005231072010@bmedcfsc-srv02.tufts.ad.tufts.edu>Show Full Headers
Complete Article Headers
X-Google-Thread: 110038,f35d7f214e6ebb35 X-Google-NewGroupId: yes X-Google-Thread: f9250,5dc541db3c8c4527 X-Google-NewGroupId: yes X-Google-Thread: 104fd2,5dc541db3c8c4527 X-Google-NewGroupId: yes X-Google-Thread: fa874,e5f42faf3ca79ee X-Google-NewGroupId: yes X-Google-Attributes: gidd668eef4dc,gid5695fe328a,gide43d82042,gidaa617e85ca,domainid0,public,usenet X-Google-Language: ENGLISH,ASCII-7-bit Path: arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!npeer03.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!post01.iad.highwinds-media.com!KNOLOGY.NET-a2kHrUvQQWlmc!not-for-mail Newsgroups: alt.cellular.attws,alt.cellular.cingular,alt.internet.wireless,ba.internet Subject: Re: OT: Emergency generators and solar photovoltaic systems? From: Larry <noone@home.com> References: <osk0561hjli19tfrgtu12b80anh8i5dj4r@4ax.com> <Xns9DC38F616A32Anoonehomecom@74.209.131.13> <i2ratc$tt7$1@news.eternal-september.org> <slrni52s9n.3sf.dcferguson@akit-ferguson.com> <3723561um0afo49klm46v2hd0cftv2s02h@4ax.com> <WYg4o.45954$YX3.29653@newsfe18.iad> <higgy-3793A3.12250429072010@news.announcetech.com> <i2sntq$udo$1@news.eternal-september.org> <higgy-ABE0C1.23345229072010@news.announcetech.com> <i2ubtr$t96$2@news.eternal-september.org> <usm556dg9jo79qvdsk1d9ckdv37nolnrcp@4ax.com> <Xns9DC5C2F6F85CDnoonehomecom@74.209.131.13> <higgy-733304.22355230072010@news.announcetech.com> <siegman-5AF1F3.09005231072010@bmedcfsc-srv02.tufts.ad.tufts.edu> Organization: Your Company Message-ID: <Xns9DC740ED21BEnoonehomecom@74.209.131.13> User-Agent: Xnews/5.04.25 X-Complaints-To: abuse@usenetserver.com Date: Sun, 01 Aug 2010 04:23:51 +0000 Lines: 97 X-Trace: 362e94c54f6d7bd73b3df31833