Hi,

I have a switching pc power supply off a 4 year old PC presently configured
for 220 V AC input and I would like to alter it to run on 110V input.  The
label says that it is a dual input type and that it may be switched
accordingly.  However, there is no such switch and I'm wondering whether two
free terminals on the PCB with a rectangle drawn around them (labelled
110V - 220V) represent the location where two switch leads are intended to
be soldered in place and when the switch is thrown to closed circuit thereby
joining these two terminals - whether that is a voltage halver (it seems to
connect to some resisters that might have that effect).  If so, then I plan
to solder in a bridge.


Any ideas?
Thanks - Rich
Technical Details
Message-ID: <oEudnc54jsu4eY2jXTWcqA@comcast.com>
Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!sn-xit-02!sn-xit-06!sn-xit-09!supernews.com!64.152.100.70.MISMATCH!sjc70.webusenet.com!news.webusenet.com!newsfeed.news2me.com!border1.nntp.aus1.giganews.com!nntp.giganews.com!nntp3.aus1.giganews.com!nntp.comcast.com!news.comcast.com.POSTED!not-for-mail

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 108c83,1e084989f39ad6a0,start
X-Google-Attributes: gid108c83,public
X-Google-Thread: f70d1,1e084989f39ad6a0,start
X-Google-Attributes: gidf70d1,public
X-Google-Thread: 10bb5c,1e084989f39ad6a0,start
X-Google-Attributes: gid10bb5c,public
X-Google-ArrivalTime: 2002-12-30 16:26:41 PST
Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!sn-xit-02!sn-xit-06!sn-xit-09!supernews.com!64.152.100.70.MISMATCH!sjc70.webusenet.com!news.webusenet.com!newsfeed.news2me.com!border1.nntp.aus1.giganews.com!nntp.giganews.com!nntp3.aus1.giganews.com!nntp.comcast.com!news.comcast.com.POSTED!not-for-mail
NNTP-Posting-Date: Mon, 30 Dec 2002 18:26:12 -0600
From: "richard kimber" <479kimber@comcast.net>
Newsgroups: alt.comp.hardware.homebuilt,sci.engr.electrical,aus.computers
Subject: power supply convert to 110V from 220V
Date: Mon, 30 Dec 2002 19:26:14 -0500
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2600.0000
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2600.0000
Message-ID: <oEudnc54jsu4eY2jXTWcqA@comcast.com>
Lines: 18
NNTP-Posting-Host: 68.37.217.177
X-Trace: sv3-fvvY/G/AbkR9ej8EEJKiIViUW/tUK0jdSCkZ+vRAxOahxCh0YnfwLvX7rjHSMUNeB5hQfHLcxYWjFOS!cXeKBmQ3uGQ1u86W4QbpJrnVWFswTbrfwUzUAPhtjtBTIquiwRs2cK1VpzYSTw==
X-Complaints-To: abuse@comcast.com
X-DMCA-Complaints-To: dmca@comcast.net
X-Abuse-and-DMCA-Info: Please be sure to forward a copy of ALL headers
X-Abuse-and-DMCA-Info: Otherwise we will be unable to process your complaint properly
X-Postfilter: 1.1