Article View: alt.dcom.telecom
Article #272Re: Mother Nature takes on UDS V.32.
From: Barton F. Bruce
Date: Tue, 12 Jan 1993 04:28
Date: Tue, 12 Jan 1993 04:28
50 lines
3026 bytes
3026 bytes
In article <1993Jan10.044936.7909@rtfm.mlb.fl.us>, luckey@rtfm.mlb.fl.us (Jon Luckey) writes: > The joys of living in florida!. > > Last night a lightning strike took out two v.32 modems I had set > up in my house. And yes, they were run through a lightning protector. Yes, but what kind of protection and how well grounded, and was there a last ditch protector for BOTH power and phone near the equipment close coupled to a COMMON GOOD ground. There is no such thing as 'good enough' ground. At least if protectors for both services are close coupled to the same 'ground', you can limit damaging potentials within your equipment. At your service entrance, you want really heavy duty lightinng arrestors dumping to a substantial ground. These may not be as fast as other things you deploy but should be able to handle lots of energy. Farther inside, the whimpier but faster spike suppressor stuff gets deployed. You never have enough. If telco is using 2 electrode carbon or even gas tubes, that can actually hurt you. You want 3 electrode gas tubes where each phone line enters. Don't ever remove their protection even if you can't get them to improve it. Just add yours after it and use the telco CO grade stuff. Doing it 'right' would have cost a lot less that what you have lost. Doing it right is NOT just getting a power and phone protecting power strip at the corner hardware store. What did you use? Did it die trying, or does it think everything is just fine and dandy after having let its protectees die? There are plenty of external things you may not be able to control. If you are fed off a transformer on the LAST pole down a long transmission line, watch out. Far better if the edison folks extend the primary to one more otherwise useless pole, and put well grounded primary arrestors THERE at the end as well as feeding your transformer one pole back via arrestors. They probably will have no protectors on the secondary, but you should have something at your service panel. $50 gets you an electrical supply house grade GE protector. Shopping can get you a Delta silicon carbide deep well submersible pump protector that has the same voltage ratings but is heavier and for less $s. Their hefty oil well rig motor protectors are wonderful, but for the wrong voltages. Just get the proper voltage unit in the same product family. For $35 it will laugh at what would trash any whimpy power strip MOV. At least 2 of the better power strip class protectors now offer insurance. Read the fine print and comply, but also add heavy front door protection at the service entrances, yourself.
Technical Details
Message-ID:
<1993Jan12.002804.11@camb.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!think.com!camb.com!bruceReferences:
<1993Jan10.044936.7909@rtfm.mlb.fl.us>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!think.com!camb.com!bruce From: bruce@camb.com (Barton F. Bruce) Newsgroups: alt.dcom.telecom Subject: Re: Mother Nature takes on UDS V.32. Message-ID: <1993Jan12.002804.11@camb.com> Date: 12 Jan 93 00:28:03 EDT References: <1993Jan10.044936.7909@rtfm.mlb.fl.us> Organization: Cambridge Computer Associates, Inc. Lines: 50