🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: alt.sci.physics.acoustics
Article #108

Re: Quartz accelerometer

#108
From: Angelo Campanella
Date: Wed, 21 Aug 1996 00:00
23 lines
2133 bytes
In article <840488007snz@measure.demon.co.uk> Andrew <Enviro@measure.demon.co.uk> writes:

>> I want to know if a quartz accelerometer is sensible to transverse
>> acceleration.

>Generally accelerometers are much less sensitive to transverse
>acceleration than forward acceleration - typically about 30 dB less
>sensitive. Some accelerometers are marked with a red spot or similar
>to indicate the direction of minimum transverse sensitivity.

Don't jump to conclusions...  Transverse sensitivity is also determeined by the
construction of the accelerometer package.  Each package design 
(crystal+inertial mass+envelope) must be evaluated.  Experimental shaker data 
is the only reliable measure.  Admittedly they are usually pretty good, but 
do look for manufacturer's test data..

Ang.


----======\/\/\/\/\/\/\/\/SOUND TECHNOLOGY\/\/\/\/\/\/\/\/\/=====-----
           "I support DOLE/KEMP[15] for a better America!"
 
Technical Details
Message-ID: <acampane.108.321A6277@postbox.acs.ohio-state.edu>
Path: arc1-ca.pugleaf.net!unknown!not-for-mail
References: <01bb8a8a.b7439480$LocalHost@spab1285> <840488007snz@measure.demon.co.uk>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 1038c2,b44615618fe400c7
X-Google-Attributes: gid1038c2,public
X-Google-Thread: f4956,b44615618fe400c7
X-Google-Attributes: gidf4956,public
X-Google-Thread: fc3b8,b44615618fe400c7
X-Google-Attributes: gidfc3b8,public
X-Google-Thread: 111a00,b44615618fe400c7
X-Google-Attributes: gid111a00,public
X-Google-Thread: 114713,b44615618fe400c7
X-Google-Attributes: gid114713,public
X-Google-Thread: f5cd5,b44615618fe400c7
X-Google-Attributes: gidf5cd5,public
X-Google-Thread: 11446d,b44615618fe400c7
X-Google-Attributes: gid11446d,public
X-Google-Thread: 10115d,b44615618fe400c7
X-Google-Attributes: gid10115d,public
From: acampane@postbox.acs.ohio-state.edu (Angelo Campanella)
Subject: Re: Quartz accelerometer
Date: 1996/08/21
Message-ID: <acampane.108.321A6277@postbox.acs.ohio-state.edu>
X-Deja-AN: 175470283
references: <01bb8a8a.b7439480$LocalHost@spab1285> <840488007snz@measure.demon.co.uk>
organization: The Ohio State University
newsgroups: alt.sci.physics.acoustics,alt.sci.physics.new-theories,fj.engr.materials,fj.news.group.sci,fj.sci.chem,fj.sci.math,fj.sci.misc,fj.sci.physics,k12.ed.science