Oki thnx this can be a good fix... but well there's not a way to set it to the proper local symbol ? "Mark Guerrieri" <mguerrieri@cmsgrp.com> ha scritto nel messaggio news:410e625a$1@newsgroups.borland.com... > In BCB6, the AnsiString(double) constructor internally calls FloatToStr, > which uses the value of the global variable DecimalSeparator to represent > the decimal point. Try something like this: > > double Value; > char OldDecimalSeparator = DecimalSeparator; > DecimalSeparator = '.'; > DataSet1->Filter = "FloatField<=" + AnsiString( Value ); > DecimalSeparator = OldDecimalSeparator; > DataSet1->Filtered=true; > > Mark > > "Michele Santucci" <michele.santucci.nospam@nospam.celinavio.it> wrote in > message news:410e51f0@newsgroups.borland.com... > > I have a field of a record (MS Access MDB file) defined as double > precision > > I need to query it at runtime using the Filter Adodataset property > > If I do something of this kind > > > > double Value; > > DataSet1->Filter = "FloatField<=" + AnsiString( double ); > > DataSet1->Filtered=true; > > > > I always got no result since the decimal separator in my local (italian) > is > > different from the default one of AnsiString. > > And then if Value=10.3 the Filter property is set to "FloatField<=10,3" > > If I try to execute the query manually using the original 10.3 notation > the > > query give the expected results. > > > > -- > > ================================ > > Michele Santucci > > Software Development Manager > > Celin Avio S.r.l. > > Via Fontevivo, 21/M 19100 La Spezia > > tel. +39-0187564080 > > ================================ > > > > > >
Technical Details
Message-ID:
<410e908d@newsgroups.borland.com>Path:
arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!news1.google.com!news.glorb.com!fr.ip.ndsoftware.net!newsfeed00.sul.t-online.de!newsfeed01.sul.t-online.de!t-online.de!newsgroups.borland.com!not-for-mailReferences:
<410e51f0@newsgroups.borland.com> <410e625a$1@newsgroups.borland.com>Show Full Headers
Complete Article Headers
X-Google-Thread: 10698b,5515ed52d6570b06 X-Google-Attributes: gid10698b,public X-Google-Language: ENGLISH,ASCII-7-bit From: "Michele Santucci" <michele.santucci@celinavio.it> Newsgroups: borland.public.cppbuilder.database.ado References: <410e51f0@newsgroups.borland.com> <410e625a$1@newsgroups.borland.com> Subject: Re: Searching on double precision fields Date: Mon, 2 Aug 2004 21:09:49 +0200 Lines: 51 Organization: Celin Avio S.r.l. X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2800.1437 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1441 NNTP-Posting-Host: 62.11.90.111 Message-ID: <410e908d@newsgroups.borland.com> X-Trace: newsgroups.borland.com 1091473549 62.11.90.111 (2 Aug 2004 12:05:49 -0700) Path: arc1-ca.pugleaf.net!g2news1.google.com!news2.google.com!news1.google.com!news.glorb.com!fr.ip.ndsoftware.net!newsfeed00.sul.t-online.de!newsfeed01.sul.t-online.de!t-online.de!newsgroups.borland.com!not-for-mail