"Some Guy" <Some@Guy.com> wrote in message news:42BDB7E5.456E1146@Guy.com... > It's a mostly sunny day here (SW Ontario) and the mid-day outdoor > conditions are about 87 degrees and 50 to 55% relative humidity. > > I have new shingles (100% asphalt, relatively light in color) on a > roof (pyramidal) with a 4:12 pitch covering an area that's about 36' x > 40'. Large vent fan and 3 passive vents near the peak. Soffits are 2 > foot wide on all 4 sides (but ventaliation is only good along 1 side > for the moment). Small fan is jury rigged in the attic space to > provide forced air circulation of the attic space and is powered with > the main roof fan. > > Temperature sensor is positioned 1/2 inch from the underside of wood > deck - so I can read the air temp immediately under the decking but > not the actual deck or exterior shingle temperature. > > Around 1 pm today the attic temperature read 120 degrees. I rigged up > some garden sprinklers on the roof and adjusted the flow to achieve > maybe 1 gallon per minute total flow. Naturally, the water exiting > the roof through the downspouts was warm to medium hot to the touch > (didn't measure the temp). > > Within about 15 to 25 minutes the attic air temp was about 100 > degrees, and it's almost 4 pm as I type this and the temp is 98.4 > degrees (outside temp is about 87). I'm sure I don't have total > coverage of roof with water spray. > > Since I'm currently re-working the soffits (adding pot-lights, > speakers, cables for CCTV, etc) I'm going to be running stuff into the > attic from the basement. I'm thinking that maybe it might be "cool" > to run a copper water line as well and permenantly mount a couple of > sprinklers that would give proper coverage to the roof and I could > turn on manually or automatically. > > Is there anything written up about residential roof cooling with water > spray? Its done very rarely but is a good idea in hot climates... especially as we are going to time of use billing on residential shortly... with roof cooling you could keep from running the AC so much under peak conditions and save a nasty demand charge billing. Using city water though leaves mineral deposits that embed into the roofing and are probably not real good for most roofs over time. thats why its not more common. If enough water can be used so that the roof stays wet and runs off then mineral deposits are less but its still an issue...some areas a big issue... others not. Poultry farms use 3000 psig water atomizer units (pumps as in pressure washers) to force water through tiny nozzels so it evaporates completely in the air...cooling the air and any mineral deposits come out as solid particles and land on the ground. You could cool your attic that way and get good results.. those are fairly expensive systems though. Or you could use an evaporative cooler to cool the attic. 1/6 hp fan motor... would save about 3/4 hp of cooling load. No mineral depost issues... but then you have a swamp cooler to maintain. Phil Scott > > Are the benefits (reduced interior cooling load and increased shingle > longevity) outweight by (maybe) shingle dammage by water spray if the > water is used on the hottest, sunniest days in the middle of the > summer?
Technical Details
Message-ID:
<d9l5s4$ap4$1@news.tdl.com>Path:
arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!news.glorb.com!newsfeed2.easynews.com!newsfeed1.easynews.com!easynews.com!easynews!news.he.net!news.tdl.com!not-for-mailReferences:
<42BDB7E5.456E1146@Guy.com>Show Full Headers
Complete Article Headers
X-Google-Thread: 104d3a,227127306d0081c2 X-Google-Thread: 10e8ea,227127306d0081c2 X-Google-Thread: fbbdb,227127306d0081c2 X-Google-Thread: 10fe96,227127306d0081c2 X-Google-Thread: f7551,227127306d0081c2 X-Google-Attributes: gid104d3a,gid10e8ea,gidfbbdb,gid10fe96,gidf7551,public X-Google-Language: ENGLISH,ASCII-7-bit Path: arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!news.glorb.com!newsfeed2.easynews.com!newsfeed1.easynews.com!easynews.com!easynews!news.he.net!news.tdl.com!not-for-mail From: "Phil Scott" <philscott@philscott.net> Newsgroups: can.construction,alt.tv.hometime,alt.building.construction,alt.tv.home-imprvment,alt.home.automation Subject: Re: Cooling attic (and home) by spraying water on roof (shingles) - good/bad? Date: Sat, 25 Jun 2005 20:02:36 -0700 Organization: The Diamond Lane Lines: 102 Message-ID: <d9l5s4$ap4$1@news.tdl.com> References: <42BDB7E5.456E1146@Guy.com> NNTP-Posting-Host: o1-dialup-66-81-75-242.rev.o1.com X-Trace: news.tdl.com 1119754949 11044 66.81.75.242 (26 Jun 2005 03:02:29 GMT) X-Complaints-To: abuse@tdl.com NNTP-Posting-Date: Sun, 26 Jun 2005 03:02:29 +0000 (UTC) X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2800.1506 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1506