"Chas Hurst" <hurst1@comcast.not> wrote in message news:0uednRz508PCbCLfRVn-1w@comcast.com... > Don't cooling towers use evaporative cooling? Yes they do... but they discharge 100% relative humidity air...but its outside so its fine...the water in the process is cooled and that cool water is used to cool most often the condensers on large tonnage refrigerated AC systems. that water typically runs 65 to 80 degrees F... sufficiently cool to cool condensers but not cool enough to be used directly for conditioning air (below 40F is required) Phil Scott > > "Phil Scott" <philscott@philscott.net> wrote in message > news:d9ocdq$2hf$1@news.tdl.com... > > > > "Some Guy" <Some@Guy.com> wrote in message > > news:42BF3E57.659FD057@Guy.com... > > > Phil Scott wrote: > > > > > > > > Doesn't a mister waste water by atomizing it and then > > the > > > > > wind will blow it away? > > > > > > > > The latent heat of evaporation for water ... > > > > > > I still don't see an effective way to arrange a residential > > cooling > > > system based on the evaporation of water. > > > > > > I don't think you can concentrate and deliver a substantial > > amount of > > > heat to a surface you can cool via evaporation. Evaporative > > cooling > > > would be effective if the heat inside a house could be > > brought to an > > > out-door device who's surface temperature is well above > > boiling and > > > the application of water would result in evaporative > > cooling. > > > > > > > Evaporative cooling would be limitlessly popular if it > > > > did not add an equal amount of humidity in the form of > > > > 'steam' to the air it was cooling to *sensibly lower > > > > termperatures. > > > > > > So what you're saying is to mistify the air circulating in a > > house in > > > order to cool it. I don't think that would work once you've > > saturated > > > the air (ie humidity > 75%) not to mention the effects of > > saturated > > > air on items in the house, the wood, the machinery, etc. > > > > I am a mechancal engineer doing these sorts of calculations > > and systems for over 40 years.. and you are entirely correct > > if the humidity is say 50% and the outside air is 90F... you > > can cool the air to 75 or so but the humidity is then up into > > the 80% range and all the problems you mention manifest. > > Thats why evaportive cooling is not used in many cases. > > > > However in areas where the relative humidity is in the 20 to > > 30% range, and the outside air is over 90F... then the supply > > air can be cooled to 70F and 50% relative humidity..that works > > very well/ > > > > > > > > > > I think only the roof makes a workable item to cool with a > > water > > > cooling. It's designed to get wet, to collect runoff, and > > gets very > > > hot in the summer, and cooling it can lead to reduction in > > cooling > > > requirements of the house. > > > > Its workable...but there are problems ..its seldom used > > because of those problems. You get to do whatever you wish > > though its yer house. Have fun. > > > > > > > > > > The only thing that makes more sense is a temporary tarp or > > canopy to > > > cover the roof during the summer (to be taken down during > > nasty > > > weather, storms, etc). > > > > Oh please. > > > > > > Phil Scott > > > > > >
Technical Details
Message-ID:
<d9quua$l83$1@news.tdl.com>Path:
arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!newshub.sdsu.edu!peer01.west.cox.net!cox.net!hwmnpeer01.phx!hwmedia!newsfeed1.easynews.com!easynews.com!easynews!news.he.net!news.tdl.com!not-for-mailReferences:
<42BDB7E5.456E1146@Guy.com> <jfOdnbddfPgDtSPfRVn-tQ@speakeasy.net> <orKdnX-MIND1ZiPfRVn-sQ@comcast.com> <42BF0BE3.2C314AE5@Guy.com> <d9nbt1$p8b$1@news.tdl.com> <42BF3E57.659FD057@Guy.com> <d9ocdq$2hf$1@news.tdl.com> <0uednRz508PCbCLfRVn-1w@comcast.com>Show Full Headers
Complete Article Headers
X-Google-Thread: 104d3a,227127306d0081c2 X-Google-Thread: 10e8ea,227127306d0081c2 X-Google-Thread: fbbdb,227127306d0081c2 X-Google-Thread: 10fe96,227127306d0081c2 X-Google-Thread: f7551,227127306d0081c2 X-Google-Attributes: gid104d3a,gid10e8ea,gidfbbdb,gid10fe96,gidf7551,public X-Google-Language: ENGLISH,ASCII-7-bit Path: arc1-ca.pugleaf.net!g2news1.google.com!news4.google.com!newshub.sdsu.edu!peer01.west.cox.net!cox.net!hwmnpeer01.phx!hwmedia!newsfeed1.easynews.com!easynews.com!easynews!news.he.net!news.tdl.com!not-for-mail From: "Phil Scott" <philscott@philscott.net> Newsgroups: can.construction,alt.tv.hometime,alt.building.construction,alt.tv.home-imprvment,alt.home.automation Subject: Re: Cooling attic (and home) by spraying water on roof (shingles)- good/bad? Date: Tue, 28 Jun 2005 00:41:14 -0700 Organization: The Diamond Lane Lines: 122 Message-ID: <d9quua$l83$1@news.tdl.com> References: <42BDB7E5.456E1146@Guy.com> <jfOdnbddfPgDtSPfRVn-tQ@speakeasy.net> <orKdnX-MIND1ZiPfRVn-sQ@comcast.com> <42BF0BE3.2C314AE5@Guy.com> <d9nbt1$p8b$1@news.tdl.com> <42BF3E57.659FD057@Guy.com> <d9ocdq$2hf$1@news.tdl.com> <0uednRz508PCbCLfRVn-1w@comcast.com> NNTP-Posting-Host: o1-dialup-66-81-120-208.rev.o1.com X-Trace: news.tdl.com 1119944459 21763 66.81.120.208 (28 Jun 2005 07:40:59 GMT) X-Complaints-To: abuse@tdl.com NNTP-Posting-Date: Tue, 28 Jun 2005 07:40:59 +0000 (UTC) X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2800.1506 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1506