Article View: can.construction
Article #253Re: Cottage foundation
From: HSchrett
Date: Sun, 31 Oct 1999 00:00
Date: Sun, 31 Oct 1999 00:00
4 lines
753 bytes
753 bytes
YOUR PILES SHOULD BE AT LEAST 12" DIA. AND 12 ' DEEP C\W 2 10MM OR 15MM RE BAR. THE IDEA IS TO HAVE MORE PILE BELOW FROST THAN ABOVE THE REBAR IS TO KEEP THE PILE FROM BREAKING WHEN THE FROST PUSHES ON THE TOP HALF OF THE PILE.YOU NEED SOME KIND OF TRUSS DESIGN OUT OF YOUR PIPE TO ACT AS BEAMS BETWEEN YOUR PILES
Technical Details
Message-ID:
<19991031170209.04203.00000789@ng-fp1.aol.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<7vhph8$4i4$1@dagger.ab.videon.ca>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 104d3a,28045658e4dc019 X-Google-Attributes: gid104d3a,public From: hschrett@aol.com (HSchrett) Subject: Re: Cottage foundation Date: 1999/10/31 Message-ID: <19991031170209.04203.00000789@ng-fp1.aol.com> X-Deja-AN: 542863621 References: <7vhph8$4i4$1@dagger.ab.videon.ca> Organization: AOL Canada http://www.aol.ca Newsgroups: can.construction X-Admin: news@aol.com