cyf@sequent.com (Cyrus Foughty) writes: >I have heard two theories about one element that affects disk transfer >rate. Help me disect these and find which is true and which is false. >Of course I feel that there will be some cases where both are true and >both are false. So, based on that I will tell you that I am dealing >with the HP97560 SCSI-2 disk drive. >Theory 1: >A higher transfer rate will result when using the outer tracks. "outer" >is defined here as "tracks that are the greatest distance from the >spindle". I.E., track numbering starting at zero. >Theory 2: >A higher transfer rate will result when using the inner tracks. >"inner" is defined here as "tracks that are the closest to the >spindle". I.E., track numbering starting at maximum track number and >decreasing. > Stuff Deleted Two months ago I didn't know about zones on disks that take advantage of the greater circumference of the outer zones. It not only increases capacity of a disk but performance as well. I was using a Seagate Elite disk to measure SCSI bus performance and found that if I moved to a different but equivalent system, I often couldn't duplicate the best performance I had achieve elsewhere. I used timex dd if=/dev/rdsk/c0t0d0s9 of=/dev/null bs=16384 count=1024 and got a bandwidth of about 2.7 MB/second but if I used slice 0, I would get about 3.6 MB/second. Evidently, the way we assign slices, s0 starts on the outer track and works in. Slice 9 is in near the hub. When the performance seem to be slice-dependent, we went to the trouble of reading the disk specification. Seagate calls the technique "Zone Bit Recording" and trademarks "ZBRtm". The disk is divided into 14 zone where the sectors per track range from 85 on the outside to 61 on the inside. Zone frequency and bytes/track correspond similarily. A Seagate document says "Variable Drive Serial Transfer Rate (26 MHz - 36 MHz) is transparent to host due to buffered interface." The variable transfer rate was not transparent in my test. We may not have tuned the buffer interface. I don't know about the HP97560, specifically, but I have heard that some HP disks do something like this but with just three zones, of 76, 88, and 96 sectors per track. Not a spokesperson for anyone. -- ====================================================================== = Martin D. Sandman ......... = = NCR Torrey Pines ..x...... = = 11010 Torreyana Road martins@TorreyPinesCA.NCR.com ....x.... = = San Diego, CA 92121 Phone: 619-597-3562 .xx..xxx. = = U. S. A. FAX: 619-597-3501 .........ants= ======================================================================
Technical Details
Message-ID:
<1992Dec23.214657.4722@TorreyPinesCA.ncr.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!psinntp!ncrlnk!torynews!martinsReferences:
<1992Dec18.145311.27416@sequent.com>Show Full Headers
Complete Article Headers
Newsgroups: comp.arch.storage Path: arc1-ca.pugleaf.net!sparky!uunet!psinntp!ncrlnk!torynews!martins From: martins@TorreyPinesCA.ncr.com (Martin Sandman 3562) Subject: Re: Inner track transfer rate vs. Outer track transfer rate Message-ID: <1992Dec23.214657.4722@TorreyPinesCA.ncr.com> Summary: Outer is Faster Sender: Martin Sandman Organization: NCR (Torrey Pines Development Center) Disclaimer: This posting does not necessarily reflect the opinions of NCR. References: <1992Dec18.145311.27416@sequent.com> Date: Wed, 23 Dec 92 21:46:57 GMT Lines: 61