I pulled some of the cross-posts So we have a Sales droid politician and a techno-jargon type with these swell sounding arguments about catastrophic failures using the Sales droids products. In article <40orfh$5an@panix.com>, Thor Lancelot Simon <tls@panix.com> wrote: >In article <DDBnou.6nD@world.std.com>, >Michael E Willett <mew@world.std.com> wrote: >>Rather than non-technical generalities, would you have a specific >>technical question you could post? > >No. I don't have any technical question for you. Nor did I post any form of >question whatsoever, as would be blindingly obvious if you hadn't removed the >entirety of my text instead of responding to it. Right bash him for not giving technical specifics and then refuse to ask a technical question. Your arguments are losing coherency and you sound hysterical. Storage Computer offers an enhanced RAID-4 style implementation THEY CALL RAID-7. Why does this upset you so much? Microsoft calls Windows an operating system, but I don't happen to agree with that, neither do I claim that using it will cause you to go blind or grow hair on your palms. > >>[NVRAM] > >I'm glad to hear that. Your basic system, with volatile cache on the other >end of a SCSI bus from the host's buffer cache, still _can not_ correctly >preserve data upon power loss, and will still lead to filesystem corruption. So it appears that SC has addressed your power loss issue with a fairly inexpensive easily swappable NVRAM memory card if you feel your system needs it. But if you use their products your gonna lose data because your so stupid you won't buy that or a UPS. Uh huh. >Correctly implemented disk storage systems don't have this problem -- only >those which circumvent the normal UNIX buffer cache semantics so that they >appear to offer better performance in simple benchmarks. So their implemention, since it does not match with _your_ idea of 'correctness' is therefore wrong, and stupid. Uh huh. Disk caches are _always_ a performance win, no matter _where_ you put them with any kind of database work. When SC claims these phenomenal thruput numbers I don't doubt it too much, though I'm sure the numbers are derived from ideal conditions. I've experimented with REAL LIVE SYSTEMS using DPT, DTC, Buslogic, and Adaptec, controllers, the former two with varying degree's of onboard cache from 4 to 16MB. When doing VERY HEAVY database work (dumping sorting, filling) for a weekend job the additional controller cache reduced the time to complete the task by as much as 40%. This was not my imagination, and was not affected by increasing the OPERATING SYSTEM buffer cache. After all everyone knows heavier objects fall faster than lighter ones right? (riiiiggggghhhhhttt!) >People who want this kind of performance increase from correctly-implemented >RAID systems can simply mount their filesystems with asynchronous metadata >writes enabled -- but note that this can lead to filesystem corruption on >power loss! Of course, so does using a "RAID 7" box without NVM *at all*. If you get bitten by a power failure you should be FIRED! This is negligence on your part, period. My machines stand a better chance of getting TOTALLY stroked by lighting, fire or hurricane (flooding), than by a power failure. In fact I can honestly say I have _never_ taken a filesystem hit from a power failure in the last 5 years or so on about 30 24Hr/day sites, I have however, had a complete melt (fire), Total destruction by lightning (The modem exploded, the inside of the computer cabinet looked like someone took an arc welder to it). and a flood (Real tough to salvage the disk under 6 feet of salty water on the outer banks of NC. All that fancy syncronous writing, and journaling is about worthless when your disk drives are all melted, or full of salt water, or have the spindle welded to the bearings. That's what backups are for. >>BTW, how does Auspex with its optional NVM approach this? > >Auspex (my usual example of cached RAID which _doesn't_ suffer from filesystem >corruption on a power hit, unlike "RAID 7") correctly handles the UNIX buffer >cache semantics, by synchronously writing filesystem metadata to disk. This Christ, over and over about the power hit, preventable with a $500 UPS. And this 'correctly handled' shit. You bitch about this SC clown, and it sorta seems to me he's REALLY toned it down since about a year ago, not to mention the fact that he has ALREADY ADDRESSED your damn totally stupid power loss corruption issue with NVRAM. Correct is when the boss walks in and says, "WOW, the system is REALLY screaming, what did you do?". >results in some degree of performance degradation when one's creating large >numbers of small files, but *is necessary* if you stick a cache between the >kernel's idea of "written to disk" and the actual disk platters. They have >specific kernel support which guarantees that this is done correctly, so that >the structure of the filesystem itself won't be corrupted on power loss. Whoopie Doo. I just change the batteries in my el-cheapo switching 2KV or 1200VA UPS's every year. If you are REALLY paranoid APC sells that new stuff with hot swappable EVERYTHING to protect your valuable data. Christ buy a tape drive will ya. If you have enough brains to set up your system CORRECTLY (you seem to like that word a lot) a power failure will shut your system down if the power stays out. Now answer this. What happens if the power drops suddenly while your jargoneous 'metadata syncronous write' Let's call it a 'superblock', or 'directory block' update for us total idiots with simple minds, is spewing data out of the write head on your disk and the accompanying surge spewy's a whole track of the directory block into oblivion? Hmmm? >RAID systems which contain a cache and sit at the other end of a SCSI bus from >the host computer *can't* handle this correctly. Therefore, instead of This is OPINION, _yours_. I don't think Mr Willet denies that his systems circumvent this syncronized writing, and in fact has stated that this is for performance reasons. While comparing the performance of "RAID-7" on a 200Mhz DEC alpha running VMS, vs a PDP-11 with standard DEC drives is pretty sleazy, you don't have to stoop to the same level with this damn cache power loss corruption issue. Jeezus, if your hard disk heads go digging into the media and start peeling it off the platter journaling and syncing writes ain't gonna help you all that much in any case. >running the risk of losing some data in files, with such a RAID system (like >the StorComp "RAID 7" RAID 4 implementation), you run the risk of losing *the >entire filesystem*. Yet for several years, this was the only kind of RAID >system that StorComp marketed at all. Can you say "irresponsible", kids? I >knew you could. This is so full of it. You spew techo-jargon about 'syncronously writing metadata' Like this "RAID-7" thingy is gonna puke all over you if you use it or something. I clearly don't see this as an issue, and neither do most of the people I know who do REAL work. The people I work with want maximal performance, with minimal risk. I frankly don't see _any_ risk in a straight power loss situation. None, zippo. You are 10 times more likely to have the building burn down around your equipment, Unless you don't have half your brain. I had to go into my main site about 3 months ago on a saturday to bring the computer back up. Someone hit the damn power pole in front of the building with a truck, knocked out the whole block for about 10 hours. I have the system set to time delay down after 60 minutes, it's on a cheapo 2KVA with an extra pair of auto batteries (For more time). The system shut itself down cleanly after a half hour, and lo and behold, had automagically powered back on and re-booted when the power came down. I wasted a trip, but it was pretty neat. That is the _only_ time the system was ever off long enough to trip in the auto-power down sequence. If you want to argue against this "RAID-7" stuff come up with a new idea besides data corruption on a power loss. It is a non-issue. -- Keith Smith <keith@ksmith.com> Free Usenet News/Newsfeeds Digital Designs (910) 423-4216/7389/7391 PO Box 85 V.34/V.34/V.32 Hope Mills, NC 28348-0085 ... Somewhere in the Styx of North Carolina ...
Technical Details
Message-ID:
<808540004.14526@ksmith.com>Path:
arc1-ca.pugleaf.net!ksmith.com!keithReferences:
<3vasmr$9g7@fdma.fdma.com> <40ivql$bj2@news.cloud9.net> <DDBnou.6nD@world.std.com> <40orfh$5an@panix.com>Show Full Headers
Complete Article Headers
Newsgroups: comp.arch.storage,comp.periphs.scsi Path: arc1-ca.pugleaf.net!ksmith.com!keith From: keith@ksmith.com (Keith Smith) Date: Tue, 15 Aug 95 22:26:44 EDT Message-ID: <808540004.14526@ksmith.com> Organization: Keith's Public Access Computer System Subject: Re: IBM now does RAID 7 service for AS/400 & other IBM platforms References: <3vasmr$9g7@fdma.fdma.com> <40ivql$bj2@news.cloud9.net> <DDBnou.6nD@world.std.com> <40orfh$5an@panix.com> Chars: 8474