From: Roger Buckthal
Date: Fri, 08 Oct 1999 00:00
Date: Fri, 08 Oct 1999 00:00
100 lines
5191 bytes
5191 bytes
Two dimensional data redundancy is defined as RAID 6 by RAB. StorageTek's Iceberg uses this technology. Unlike conventional RAID controllers that use an XOR to compute redundant information, RAID 6 uses P+Q calculation - two simultaneous equations with two unknowns. Statistically this is much greater availability then a simple XOR protection scheme, however it does suffer from greater performance overhead (two disks must be updated on a partial stripe write). Roger HP Enterprise Storage Division Bill Todd wrote in message <7smbrs$7lb$1@pyrite.mv.net>... >[Forgive the reply to myself - just to clarify:] > >I inadvertently munged two concepts together, I think: I do understand how >a 2-dimensional array arrangement works where there are m * n data disks >(conceptually, an m by n rectangle) and m + n parity disks (arranged along >two sides of the rectangle, providing parity in 2 dimensions), but think I >have heard mention of some means of adding a second parity disk to a simple >array that makes double-disk failures tolerable, which is what I'm curious >about (since I don't see off-hand how it could be done). > >Thanks, - bill > >Bill Todd <billtodd@foo.mv.com> wrote in message >news:7sll6t$l8j$1@pyrite.mv.net... >> But it still takes more disks: 3*n vs. 2*(n+1). That said, given disk >> prices these days, I wonder how important that is, even in read-mostly (or >> full-stripe-write) environments where RAID-5 has no performance penalty. >> >> I've never investigated the 'two-dimensional parity' approach that >> supposedly uses 2 parity drives in a manner that allows *any two* drives >in >> a RAID set to fail simultaneously without data loss: I assume it carries >> greater write and rebuild overhead than RAID-5, but would be interested in >a >> pointer to a good discussion. >> >> - bill >> >> Kjell Tore Nannestad <knannest@c2i.net> wrote in message >> news:37EE4665.C2FF28E@c2i.net... >> > I guess it's easier to make a second mirror using RAID 1. >> > . >> > >> > >> > prostorage wrote: >> > >> > > In article <37EB92A6.8579E99A@ultrafast.net.no.sp.am>, >> > > RAIDER@ultrafast.net.no.sp.am says... >> > > >Jim, let it be known that a hot spare drive in a RAID 5 setup does >> > > >NOTHING to protect from a failure of more than one drive at a time. >> What >> > > >it does do, however, it minimizes MTTR (Mean Time To Repair) because >> > > >most raid controllers will automatically initiate a rebuild of a >failed >> > > >drive onto a hot spare. Should another disk fail while the rebuild is >> > > >still in progress - the RAID set and all the data on it will be lost. >> > > >RAIDER >> > > > >> > > >Jim Pappe wrote: >> > > >> >> > > >> with Raid 5 plus hot spare - 2 drive can fail .. >> > > >> www.raidexpert.com >> > > >> >> > > >> > > RAIDER is correct >> > > a second "warm" or "hot" spare would do nothing to save you if 2 >> > > drives went down at the same time >> > > >> > > the only way that i know of to live through the failure of 2 drives >> > > simultaneously is to have 2 separate RAID 5's running as the >> > > mirrored drives in a RAID 1 (& we've done this) >> > > >> > > _____ . . >> > > ' \\ . . |>> >> > > O// . . | >> > > \_\ . . | >> > > | | . 800-324-6711 / 800-720-7618 fax . . | >> > > / | . mailto:prostorage@earthlink.net . . . | >> > > / .| http://www.geocities.com/scsiperipherals/ . . . | >> > > / . | http://kalypso.cybercom.net/scsiper/andys.html .. . o >> > > ---------------------------------------------------------------------- >> > > Authorized - DIRECT VAR/VAD/Distributor for new SCSI/FC-AL peripherals >> > > from: IBM, Seagate, Quantum, Adaptec, Sony, Yamaha, ATTO, JNI, ATL ect >> > >> >> > >
Technical Details
Message-ID:
<7tltlk$de1$1@hpbs1500.boi.hp.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<7nl85m$3nn$1@newton.pacific.net.sg> <37E1425E.9F4D1F3B@t-online.de> <937569107.3977.0.nnrp-11.9e98b72c@news.demon.co.uk> <37e660eb.12904299@news.earthlink.net> <7sehd5$80a@journal.concentric.net> <37EB92A6.8579E99A@ultrafast.net.no.sp.am> <7sj2gh$fq1$2@fir.prod.itd.earthlink.net> <37EE4665.C2FF28E@c2i.net> <7sll6t$l8j$1@pyrite.mv.net> <7smbrs$7lb$1@pyrite.mv.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: f4d7c,813a29bed80cb2f6 X-Google-Attributes: gidf4d7c,public X-Google-Thread: 10e1c8,813a29bed80cb2f6 X-Google-Attributes: gid10e1c8,public X-Google-Thread: 1144af,813a29bed80cb2f6 X-Google-Attributes: gid1144af,public From: "Roger Buckthal" <roger_buckthal@hp.com> Subject: Re: RAID 1 or 5 ? Date: 1999/10/08 Message-ID: <7tltlk$de1$1@hpbs1500.boi.hp.com> X-Deja-AN: 534510952 References: <7nl85m$3nn$1@newton.pacific.net.sg> <37E1425E.9F4D1F3B@t-online.de> <937569107.3977.0.nnrp-11.9e98b72c@news.demon.co.uk> <37e660eb.12904299@news.earthlink.net> <7sehd5$80a@journal.concentric.net> <37EB92A6.8579E99A@ultrafast.net.no.sp.am> <7sj2gh$fq1$2@fir.prod.itd.earthlink.net> <37EE4665.C2FF28E@c2i.net> <7sll6t$l8j$1@pyrite.mv.net> <7smbrs$7lb$1@pyrite.mv.net> X-MimeOLE: Produced By Microsoft MimeOLE V4.72.3612.1700 X-Complaints-To: usenet@news X-Trace: hpbs1500.boi.hp.com 939424244 13761 15.62.125.100 (8 Oct 1999 23:10:44 GMT) Organization: Hewlett Packard NNTP-Posting-Date: 8 Oct 1999 23:10:44 GMT Newsgroups: comp.arch.storage,comp.sys.ibm.pc.hardware.storage,fido.ger.storage