🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.arch
Article #10727

Re: skip instructions

#10727
From: 213 Richard Wilmot
Date: Wed, 08 May 1991 23:29
45 lines
2963 bytes
>It seems to me the real reason was variable length instructions.  DEC
>machines up through the PDP-10 all had fixed length single word
>instructions, so it was obvious what skipping one would mean.  Ditto the IBM
>scientific machines up through the 7094, and their clones such as the GE
>635.  The IBM 360 and PDP-11 both had variable length instructions and
>condition codes.
>
>Variable length instructions make skips a lot less appealing.  I once used a
>machine that had single word skips but a combination of one and two word
>instructions (Varian 620, for you historians) and some impressively strange
>bugs resulted from skipping into the middle of a two-word instruction.
>
Oooh. Skipping into the middle of instructions. Honeywell built a 
family of machines starting with the H200 which were punctuation
machines. Storage manipulation started at an address and continued
until the source had a specified punctuation mark (two extra, non-data
bits) set (on). This was really dreamy for compilers and text manipulation.
Addresses were of several different lengths and there were instructions
to change the current address width (CAM: Change Addressing Mode).
Instructions consisted of opcode followed by register [?] and 
displacements (of the correct length for current addressing mode)
[this is from my hazy memory - didn't have room for those manuals].
Instruction would begin extraction and execution on seeing the word
mark that was set at the end of every instruction. So you could
have fully coded instructions that were presently off because their
word marks (in the preceding instructions) were not set, then
your program would turn those instructions on by setting the punctuation
bit. But if you branched to one of these instruction addresses then it
would extract and execute from the following word mark. So instructions
not preceded by word marks were turned off unless they were branched to.
Dijkstra?? :-)   GOTOs worked, they always did something.

Punctuation machines were fun. We need to bring them back to handle
null terminated strings. :-))



>John R. Levine, IECC, POB 349, Cambridge MA 02238, +1 617 492 3869
>johnl@iecc.cambridge.ma.us, {ima|spdcc|world}!iecc!johnl
>Cheap oil is an oxymoron.


-- 
  Dick Wilmot  | I declaim that Amdahl might disclaim any of my claims.
                 (408) 746-6108
Technical Details
Message-ID: <7b=C02CO071s01@JUTS.ccc.amdahl.com>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!apple!amdahl!JUTS!rbw00
References: <1182@opus.NMSU.Edu> <1991May05.174307.8952@iecc.cambridge.ma.us>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!apple!amdahl!JUTS!rbw00
From: rbw00@ccc.amdahl.com (  213  Richard Wilmot)
Newsgroups: comp.arch
Subject: Re: skip instructions
Summary: Wierder skipping
Keywords: Punctuation,Honeywell,item marks,word marks
Message-ID: <7b=C02CO071s01@JUTS.ccc.amdahl.com>
Date: 8 May 91 23:29:07 GMT
References: <1182@opus.NMSU.Edu> <1991May05.174307.8952@iecc.cambridge.ma.us>
Reply-To: rbw00@JUTS.ccc.amdahl.com (  213  Richard Wilmot)
Distribution: comp
Organization: Amdahl Corporation, Sunnyvale CA
Lines: 45