Article View: comp.arch
Article #11084Re: COMPAQ PROPOSED SCALABLE I/O ARCHITECTURE
From: cecchi.rchvmx.vnet.ibm.com Del C...
Date: Wed, 16 Dec 1992 16:45
Date: Wed, 16 Dec 1992 16:45
11 lines
1115 bytes
1115 bytes
Why wouldn't you use one of the defined versions of the already specified IEEE-1596-1992 or Scalable Coherent Interface? If you adopt the 1596.3 signaling levels, you will be able to buy the core logic from LSI Logic or perhaps National. Dolphin SCI Technology will be happy to provide advice. All in all, you are about three years late if you want to invent, but right on time if you want to use. -- Del Cecchi cecchi@rchvmx.vnet.ibm.com
Technical Details
Message-ID:
<1992Dec16.164548.31201@rchland.ibm.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!newsgate.watson.ibm.com!yktnews!admin!signa!cecchiReferences:
<1992Dec15.171554.2781@twisto.eng.hou.compaq.com>Show Full Headers
Complete Article Headers
Newsgroups: comp.arch Path: arc1-ca.pugleaf.net!sparky!uunet!newsgate.watson.ibm.com!yktnews!admin!signa!cecchi From: cecchi.rchvmx.vnet.ibm.com (Del Cecchi)@rchland.vnet.ibm.com Subject: Re: COMPAQ PROPOSED SCALABLE I/O ARCHITECTURE Message-ID: <1992Dec16.164548.31201@rchland.ibm.com> Sender: cecchi@signa.rchland.ibm.com (Del Cecchi) Date: Wed, 16 Dec 1992 16:45:48 GMT Disclaimer: This posting represents the poster's views, not necessarily those of IBM References: <1992Dec15.171554.2781@twisto.eng.hou.compaq.com> Nntp-Posting-Host: signa.rchland.ibm.com Organization: IBM Rochester Keywords: I/O, Point-to-Point, High Performance, Low Cost, Bus Lines: 11