Article View: comp.dcom.cabling
Article #23Re: BNC cabling problem
From: John Lundgren
Date: Mon, 18 Mar 1996 00:00
Date: Mon, 18 Mar 1996 00:00
61 lines
3791 bytes
3791 bytes
Dino Hsu (dino1@ms1.hinet.net) penned: : I am a novice network administrator, I need some answers on BNC : cabling, please hlep me, if you know the answers and if you have : similar experience. First off, BNC is the connector on the end of the cable. The cable is RG-58 or similar 50 ohm coaxial cable. : 1. What is the length limits of BCN cabels ? The max total length and : the max segment length ? It's called 10Base2 for 200 meters, actually 185 meters. : 2. If the total length is too long, what's gonna happen ? Is it that : no nodes' gonna connect to any servers, or just those nodes that are : too far from the servers will encounter connection problems ? It's like if you step on a crack, it may break your mother's back. Try it and find out. : 3. If I would like to get the length longer, should I get a repeater, : a bridge, or a router ? What's the difference ? RTFM, that is read the FAQ. Posted here or to the comp.answers newsgroups, or check my .sig for another URL. : 4. I discoverd a phenomenon lately, if the total length is : approximately double the limit, and I position two servers as one near : one end and the other near the orther end, there will be no connection : problems. So may I say the server can be treated as a kind of repeater : or router? Sounds fairly whacko to me. : 5. What's the benifits if I use a hub instead of BNC cabels? Take : into consideration the necessity to rebuild the cables distribution : and there are cosmetic issues for my office. One break in a 10BaseT cable brings down a single workstation. One break in a 10Base2 cable brings down the whole network. : 6. Are there any standard diagnosis procedures when some nodes get : connection problems ? What kind of tools or implements are required ? : Are there any prevention procedures or network design principles? : Thanks in advance. RTFM. Use common sense. Keep a few lengths of coax and terminating resistors handy to isolate segments. etc. etc. -- #======P=G=P==k=e=y==a=v=a=i=l=a=b=l=e==u=p=o=n==r=e=q=u=e=s=t======# | John Lundgren - Elec Tech - Info Tech Svcs. | jlundgre@ | | Rancho Santiago Community College District | deltanet.com | | 17th St at Bristol \ Santa Ana, CA 92706 | http://rsc.rancho| | My opinions are my own, and not my employer's. | .cc.ca.us | | Most FAQs are available through Thomas Fine's WWW FAQ archive: | |http://www.cis.ohio-state.edu:80/hypertext/faq/usenet/FAQ-List.html| | "You can flame your brains out -- it won't take long." | #===T=u=z=l=a==C=o=m=p=a=n=y=.=.===t=h=r=e=e='=s==L=e==C=r=o=w=d=!==#
Technical Details
Message-ID:
<4iiiqu$qh4@news02.deltanet.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<4i6gf0$2k2@netnews.hinet.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: fe659,f01016258948b74f,start X-Google-Attributes: gidfe659,public X-Google-Thread: 103bf6,f01016258948b74f,start X-Google-Attributes: gid103bf6,public X-Google-Thread: fc1d4,f01016258948b74f,start X-Google-Attributes: gidfc1d4,public X-Google-Thread: fe31e,f01016258948b74f,start X-Google-Attributes: gidfe31e,public X-Google-Thread: fa939,f01016258948b74f,start X-Google-Attributes: gidfa939,public X-Google-Thread: f8bf7,f01016258948b74f,start X-Google-Attributes: gidf8bf7,public From: jlundgre@delta1.deltanet.com (John Lundgren) Subject: Re: BNC cabling problem Date: 1996/03/18 Message-ID: <4iiiqu$qh4@news02.deltanet.com> X-Deja-AN: 143054582 references: <4i6gf0$2k2@netnews.hinet.net> followup-to: comp.dcom.cabling,bit.listserv.novell,tw.bbs.comp.novell,comp.os.netware.misc,comp.os.netware.connectivity,comp.os.netware.security organization: Delta Internet Services, Anaheim, CA newsgroups: comp.dcom.cabling,bit.listserv.novell,tw.bbs.comp.novell,comp.os.netware.misc,comp.os.netware.connectivity,comp.os.netware.security