🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.dcom.lans.ethernet
Article #1068

Re: 10T and number of twists per foot.

#1068
From: tanemeth
Date: Wed, 27 Jan 1993 23:40
16 lines
1287 bytes
In article <slendt.105.727652267@unomaha.edu>, slendt@unomaha.edu (Steven Lendt) writes:
> How many twists per foot in solid core unshelded twisted pair wire are
> needed to make it live up to level 3 10baseT spec?

EIA568 spec. says "7 to 10 twists per foot".  Most cables I have seen interpret
this as 7 for pair 1 (blue), 8 for pair 2 (orange), 9 for pair 3 (green) and
10 for pair 4 (brown).

> Also, how many punch blocks (old 66 type) is it safe to go through if the
> total wire length is not greater than 75 meters?

Always as FEW AS POSSIBLE.  Should ideally be 3 max.  From memory, you need to
deduct 2m from max usable length for each extra cross-connect.


Tom Nemeth
Technical Details
Message-ID: <1993Jan28.091022.1@economics.adelaide.edu.au>
Path: arc1-ca.pugleaf.net!sparky!uunet!opl.com!hri.com!spool.mu.edu!howland.reston.ans.net!paladin.american.edu!gatech!darwin.sura.net!sgiblab!munnari.oz.au!yoyo.aarnet.edu.au!news.adelaide.edu.au!economics.adelaide.edu.au!tanemeth
References: <slendt.105.727652267@unomaha.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!opl.com!hri.com!spool.mu.edu!howland.reston.ans.net!paladin.american.edu!gatech!darwin.sura.net!sgiblab!munnari.oz.au!yoyo.aarnet.edu.au!news.adelaide.edu.au!economics.adelaide.edu.au!tanemeth
From: tanemeth@economics.adelaide.edu.au
Newsgroups: comp.dcom.lans.ethernet
Subject: Re: 10T and number of twists per foot.
Message-ID: <1993Jan28.091022.1@economics.adelaide.edu.au>
Date: 27 Jan 93 23:40:22 GMT
References: <slendt.105.727652267@unomaha.edu>
Organization: Economics, University of Adelaide
Lines: 16
NNTP-Posting-Host: eco.economics.adelaide.edu.au