In article <C0M9sL.Mxs@iron.hq.aflc.af.mil>, fenton@iron.hq.aflc.af.mil (George I. Fenton) writes:
> ... I have had cases of PC
> workstations plugged into a bad power outlet with bad ground, and the PCs
> start to use the 10Base2 as a ground source. ...
Then your PC is broken. The BNC connector is supposed to be completely
electrically isolated from the system ground. Multiple grounding of a thinnet
is a good way to up your error rate. Faulty interface cards are one way to
cause this; T-pieces and barrel-connectors touching against random pieces of
metalwork are another.
--
George D M Ross, Department of Computer Science, University of Edinburgh
Kings Buildings, Mayfield Road, Edinburgh, Scotland, EH9 3JZ
Tel: 031-650 5147 Internet: gdmr@dcs.ed.ac.uk JANET: gdmr@uk.ac.ed.dcs
Technical Details
Message-ID:
<C0onyJ.7z9@dcs.ed.ac.uk>Path:
arc1-ca.pugleaf.net!sparky!uunet!pipex!unipalm!uknet!edcastle!dcs.ed.ac.uk!gdmrReferences:
<1993Jan9.110551.1@kodiak.sfpp.com> <C0M9sL.Mxs@iron.hq.aflc.af.mil>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!pipex!unipalm!uknet!edcastle!dcs.ed.ac.uk!gdmr From: gdmr@dcs.ed.ac.uk (George Ross) Newsgroups: comp.dcom.lans.ethernet Subject: Re: Thinwire specs/problem? Message-ID: <C0onyJ.7z9@dcs.ed.ac.uk> Date: 11 Jan 93 09:35:07 GMT References: <1993Jan9.110551.1@kodiak.sfpp.com> <C0M9sL.Mxs@iron.hq.aflc.af.mil> Sender: cnews@dcs.ed.ac.uk (UseNet News Admin) Organization: Department of Computer Science, Edinburgh University Lines: 14