In designing an FDDI net we used to use the following design specs:
1dB max loss per mated ST connector pair and .5dB max loss per splice.
I'm beginning to wonder if this is ultra-conservative and am toying
with the idea of changing that to .5dB max per mated connector pair
and .2dB max loss per splice (mechanical). I figure a 2dB margin in
the budget will take care of any slop. We do a tight QA on all
installations and from what I've seen in terms of connector loss the
.5dB max is reasonable.
What are other folks doing? Comments?
--
Merike Kaeo merike@alw.nih.gov
National Institutes of Health (301) 402-1548
o
\
\0/
||==================|=====||
||-+-+-+-+-+-+-+-+-/\+-+-+||
||=================\=\====||
|| ||
|| ||
|| ||
......kill or be killed.....
Technical Details
Message-ID:
<1992Sep14.152831.11360@alw.nih.gov>Path:
arc1-ca.pugleaf.net!sparky!uunet!nih-csl!alw.nih.gov!merikeShow Full Headers
Complete Article Headers
Newsgroups: comp.dcom.lans.fddi Path: arc1-ca.pugleaf.net!sparky!uunet!nih-csl!alw.nih.gov!merike From: merike@alw.nih.gov (Merike Kaeo) Subject: fiber budgets Message-ID: <1992Sep14.152831.11360@alw.nih.gov> Sender: postman@alw.nih.gov (AMDS Postmaster) Organization: National Inst. of Health, DCRT, CSL Date: Mon, 14 Sep 1992 15:28:31 GMT Lines: 31