In article <1992Sep14.152831.11360@alw.nih.gov> merike@alw.nih.gov (Merike Kaeo) writes: >In designing an FDDI net we used to use the following design specs: >1dB max loss per mated ST connector pair and .5dB max loss per splice. >I'm beginning to wonder if this is ultra-conservative and am toying >with the idea of changing that to .5dB max per mated connector pair >and .2dB max loss per splice (mechanical). I figure a 2dB margin in >the budget will take care of any slop. We do a tight QA on all >installations and from what I've seen in terms of connector loss the >.5dB max is reasonable. > >What are other folks doing? Comments? > I use to make up fiber and FDDI connections. I have installed several FDDI LAN's including AMD's ANTC. Typical connector loss should not exceed .7dB. I was able to achieve a loss of less then .3dB at the connector on most of my work. Regards, Dave Turner -- ------------------------------------------------------------------------------- David P. Turner Internet: turner@ctron.com Cabletron Systems Inc. Compuserve: 76702,1733 Voice: (603) 335-9400 E-mail Cabletron Support Internet - support@ctron.com
Technical Details
Message-ID:
<5060@balrog.ctron.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!haven.umd.edu!darwin.sura.net!zaphod.mps.ohio-state.edu!sample.eng.ohio-state.edu!purdue!mentor.cc.purdue.edu!noose.ecn.purdue.edu!samsung!balrog!turnerReferences:
<1992Sep14.152831.11360@alw.nih.gov>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!haven.umd.edu!darwin.sura.net!zaphod.mps.ohio-state.edu!sample.eng.ohio-state.edu!purdue!mentor.cc.purdue.edu!noose.ecn.purdue.edu!samsung!balrog!turner From: turner@ctron.com (David Turner) Newsgroups: comp.dcom.lans.fddi Subject: Re: fiber budgets Message-ID: <5060@balrog.ctron.com> Date: 15 Sep 92 19:27:18 GMT References: <1992Sep14.152831.11360@alw.nih.gov> Sender: usenet@balrog.ctron.com Reply-To: turner@olympus.ctron.com (David Turner) Organization: Cabletron Systems INc. Lines: 28