Article View: comp.dcom.modems.cable
Article #339Re: running network cable through windows and walls?
From: Matt Dillon
Date: Wed, 02 Sep 1998 00:00
Date: Wed, 02 Sep 1998 00:00
44 lines
2625 bytes
2625 bytes
:In article <MPG.10572b78acbc04c39896ca@ispnews.walltech.com>,
:Philip J. Koenig <For_Email@ddress.see.below_plea.se> wrote:
:>In article <01bdd698$fe212500$8028a8c0@jb.zedak.com>, jb@zedak.keepyourspam.com
:>writes...
:>> Daniel Erskine <netsup75@edwardjones.com> wrote in article
:>> <35EACDBE.237D36B8@edwardjones.com>...
:..
:>
:>The reason that using correct cable is important are as follows:
:>
:>1 - Terminators and NIC's are 75 ohm, if the cable is not, you end up
:> with reflections that play hell with the waveforms and thus, data
:> integrity.
10base2 uses 50 ohm coax and 50 ohm termination.
:>2 - The reason distance is a factor (and why the IEEE specifies a
:> maximum length for 10base2 segments) is due to the rate of signal
:> propagation. Since 802.3 collision detection relies on a known rate
:> of propagation and maximum segment length (tailoring it's "collision
:> listen window" accordingly), if you run out-of-spec cabling you run
:> the risk that collision-detection no longer works correctly, which
:> causes a host of problems including runt packets, late-collisions,
:> etc.
The collision window is not the maximum segment length, It's the
preamble period plus I think the MAC header (don't quite remember but
I think it's the first 64 bit times or something like that). If
a collision occurs after that point, you get a 'late collision' which,
which detectable, is a very serious error.
-Matt
:>Phil
:>
:>
:>--
:>Philip J. Koenig The Electric Kahuna Organization [see below]
--
Matthew Dillon Engineering, HiWay Technologies, Inc. & BEST Internet
Communications
<dillon@best.net> (Please include original email in any response)
Technical Details
Message-ID:
<6sk60s$j7d$1@flea.best.net>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<6rcoho$284$1@nnrp1.dejanews.com> <35EACDBE.237D36B8@edwardjones.com> <01bdd698$fe212500$8028a8c0@jb.zedak.com> <MPG.10572b78acbc04c39896ca@ispnews.walltech.com>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 113850,4e89f3904072fcfe X-Google-Attributes: gid113850,public X-Google-Thread: 1159e3,4e89f3904072fcfe X-Google-Attributes: gid1159e3,public X-Google-Thread: fa874,4e89f3904072fcfe X-Google-Attributes: gidfa874,public From: dillon@best.net (Matt Dillon) Subject: Re: running network cable through windows and walls? Date: 1998/09/02 Message-ID: <6sk60s$j7d$1@flea.best.net> X-Deja-AN: 387224535 References: <6rcoho$284$1@nnrp1.dejanews.com> <35EACDBE.237D36B8@edwardjones.com> <01bdd698$fe212500$8028a8c0@jb.zedak.com> <MPG.10572b78acbc04c39896ca@ispnews.walltech.com> X-Trace: 904764256 2795 dillon 206.184.139.131 Organization: Best Internet Communications, Inc. Newsgroups: comp.dcom.modems.cable,ba.internet,alt.home.repair