Article View: comp.dcom.modems.cable
Article #343Re: running network cable through windows and walls?
From: Philip J. Koenig
Date: Thu, 03 Sep 1998 00:00
Date: Thu, 03 Sep 1998 00:00
79 lines
4518 bytes
4518 bytes
In article <6sk60s$j7d$1@flea.best.net>, dillon@best.net writes... > :In article <MPG.10572b78acbc04c39896ca@ispnews.walltech.com>, > :Philip J. Koenig <For_Email@ddress.see.below_plea.se> wrote: > :>In article <01bdd698$fe212500$8028a8c0@jb.zedak.com>, jb@zedak.keepyourspam.com > :>writes... > :>> Daniel Erskine <netsup75@edwardjones.com> wrote in article > :>> <35EACDBE.237D36B8@edwardjones.com>... > :.. > :> > :>The reason that using correct cable is important are as follows: > :> > :>1 - Terminators and NIC's are 75 ohm, if the cable is not, you end up > :> with reflections that play hell with the waveforms and thus, data > :> integrity. > > 10base2 uses 50 ohm coax and 50 ohm termination. GACK... sorry my mistake. Too many years working with cable TV stuff I guess.. :) > :>2 - The reason distance is a factor (and why the IEEE specifies a > :> maximum length for 10base2 segments) is due to the rate of signal > :> propagation. Since 802.3 collision detection relies on a known rate > :> of propagation and maximum segment length (tailoring it's "collision > :> listen window" accordingly), if you run out-of-spec cabling you run > :> the risk that collision-detection no longer works correctly, which > :> causes a host of problems including runt packets, late-collisions, > :> etc. > > The collision window is not the maximum segment length, It's the > preamble period plus I think the MAC header (don't quite remember but > I think it's the first 64 bit times or something like that). If > a collision occurs after that point, you get a 'late collision' which, > which detectable, is a very serious error. > > -Matt > Yes, "collision window" is not the maximum segment length. To be more specific, the time allotted for listening for collisions is specific (I don't remember, possibly 64 bit times as you say) and it is a direct function of A) the velocity of propagation in the coax, which is specified in the 802.3 spec to be within a certain known range and B) the length of the segment. Given standard "thinnet" cable, if the length is kept within the 802.3- specified maximums, the propagation (or "round-trip") time is such that it does not exceed the "collision listen window". The risk is of course if the cable is too long, the transceivers on the wire will stop listening for collisions on the wire when they may still be occurring. Some NIC's had/have a mode for "extended segment length", it is not technically 802.3 compliant. And by the same token (no pun intended), if you really wanted to run a longer segment length, you could also run cable that had a faster velocity of propagation than the 802.3 standard originally called for. However in the absence of a thorough knowledge of the physics and transmission-line theory involved (and requisite test equipment), the obvious solution is simply to use 802.3 compliant cable and adhere to 802.3-recommended maximum cable lengths. (and other recommendations like maximum 30 taps per segment, no short stubs, etc.. :-) Phil -- Philip J. Koenig The Electric Kahuna Organization [see below] -----------------Computers & Communications for the New Millenium------------- References to my email address in this message have been modified to foil address-collection robots. If you wish to send email, use the following address by removing numbers and spaces: pjkunet64 @ ekahuna27 . c o m
Technical Details
Message-ID:
<MPG.10580827cc6440dc9896cb@ispnews.walltech.com>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<6rcoho$284$1@nnrp1.dejanews.com> <35EACDBE.237D36B8@edwardjones.com> <01bdd698$fe212500$8028a8c0@jb.zedak.com> <MPG.10572b78acbc04c39896ca@ispnews.walltech.com> <6sk60s$j7d$1@flea.best.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: fa874,4e89f3904072fcfe X-Google-Attributes: gidfa874,public X-Google-Thread: 113850,4e89f3904072fcfe X-Google-Attributes: gid113850,public X-Google-Thread: 1159e3,4e89f3904072fcfe X-Google-Attributes: gid1159e3,public From: For_Email@ddress.see.below_plea.se (Philip J. Koenig) Subject: Re: running network cable through windows and walls? Date: 1998/09/03 Message-ID: <MPG.10580827cc6440dc9896cb@ispnews.walltech.com> X-Deja-AN: 387431425 References: <6rcoho$284$1@nnrp1.dejanews.com> <35EACDBE.237D36B8@edwardjones.com> <01bdd698$fe212500$8028a8c0@jb.zedak.com> <MPG.10572b78acbc04c39896ca@ispnews.walltech.com> <6sk60s$j7d$1@flea.best.net> X-Trace: news14.ispnews.com 904816702 208.211.98.197 (Thu, 03 Sep 1998 05:58:22 EDT) Organization: Computers & Communications NNTP-Posting-Date: Thu, 03 Sep 1998 05:58:22 EDT Newsgroups: comp.dcom.modems.cable,ba.internet,alt.home.repair