Hello net,
For remote printing we have following configuration installed:
---
+-----+ | +-------+
| VAX +------+ | +----
+-----+ | +------+ | +------
+----+router+------ WAN ------+Trouter+-------
+-----+ | +------+ | + +-------+
| CPT +------+ | +------+Printer|
+-----+ | +-------+ +-------+
|
---
The CPT, router and Trouter are all cisco's (8.2/8.3). The VAX has a LAT queue
defined. The CPT translates LAT to telnet and sends the data directly to a
port on the Trouter using a definition like:
translate lat TLPRFR1 tcp 130.142.250.2 port 6009 Stream quiet max-users 1
This all works but with a some problems that makes that the queue is
regularly 'stalled' with the message 'data set hangup'. We must stop and
start the queue and clear the line on the Trouter where the printer is
connected to. Result is that printfiles restart from the beginning (annoying
if you send a bill twice though we can use the money :-) ).
Does anyone have a similar setup? Any comments? Alternative sulutions?
The remote site is an sales office. Maybe some PC's but no unix/vms
systems around.
Please respond to me. I'll summarize interesting info to the net.
Thanks,
--
Aloys Roes, <> Email: roes@seri.philips.nl
Philips SERI-MPN, /\ SERI : roes:phcoms
P.O.Box 218, Bldg VN-513, \/ Tel. : + 31 (0)40 784 899
5600 MD Eindhoven, The Netherlands. <> Fax. : + 31 (0)40 782 900
Technical Details
Message-ID:
<1992Aug12.152342.22501@phcomgw.seri.philips.nl>Path:
arc1-ca.pugleaf.net!sparky!uunet!mcsun!sun4nl!relay.philips.nl!phcoms.seri.philips.nl!roesShow Full Headers
Complete Article Headers
Newsgroups: comp.dcom.sys.cisco Path: arc1-ca.pugleaf.net!sparky!uunet!mcsun!sun4nl!relay.philips.nl!phcoms.seri.philips.nl!roes From: roes@phcoms.seri.philips.nl.seri.philips.nl (Aloys Roes) Subject: Experiences with CPT for remote printing Message-ID: <1992Aug12.152342.22501@phcomgw.seri.philips.nl> Keywords: CPT Sender: news@phcomgw.seri.philips.nl Organization: SERI-MPN Network Services, Philips C&P, Eindhoven, The Netherlands X-Newsreader: Tin 1.1 PL4 Date: Wed, 12 Aug 1992 15:23:42 GMT Lines: 39