In article <93012.103138RHUNTER@ESOC.BITNET>, <RHUNTER@ESOC.BITNET> wrote: > > I have done some more digging into the validity of 2 areas on 1 Ethernet. > > Page 2-27 of VMS Networking Manual april 88 for VMS v5.0 > > "2.4.4.3 Area Routing on Ethernet > All nodes on an Ethernet need not be in the same area; you can configure > more than one area on a single ethernet. The areas on the same Ethernet are > logically seperate from each other..... > Section A.6 illustrates area routing on an Ethernet" > > looks like everything will be OK. > > Just a reminder of the problem: > Is it possible to run more than 1 DECnet area in a Cisco? > > I think you use the Address Translation Gateway to start two processes > > decnet 0 routing > > decnet 0 node-type area > ... > but you do NOT configure any translations.... > the 2 routing processes should then run seperately, and only communicate > via the common Ethernet interfaces. > > It then becomes a question of how many Ethernets you need to share areas > on, as you need to use 2 interfaces per Ethernet. > > Once again, a reminder that this comes untested! > > Ray Hunter > RHUNTER@ESOC.BITNET > Cray Systems on Contract to the European Space Agency > #include <std.disclaimer> You may have many DECnet areas on the same segment, but each area should have its own router. The cisco interface can only have one DECnet address, thus can be the router for only one DECnet area, as an area router must be in the same area that it is going to route for. You could designate one of your VAXen an area router for the other area though. Alain Martineau Hydro Quebec amartineau@nccr.felix.hydro.qc.ca
Technical Details
Message-ID:
<martineau-120193074624@macmartineau.ccr.hydro.qc.ca>Path:
arc1-ca.pugleaf.net!sparky!uunet!newsflash.concordia.ca!hobbit.ireq.hydro.qc.ca!macmartineau.ccr.hydro.qc.ca!userReferences:
<1993Jan6.184259.8546@ferrari.nmc.ed.ray.com> <93012.103138RHUNTER@ESOC.BITNET>Show Full Headers
Complete Article Headers
Newsgroups: comp.dcom.sys.cisco Path: arc1-ca.pugleaf.net!sparky!uunet!newsflash.concordia.ca!hobbit.ireq.hydro.qc.ca!macmartineau.ccr.hydro.qc.ca!user From: martineau@MacMartineau.ccr.hydro.qc.ca (Alain Martineau) Subject: Re: DECnet areas Message-ID: <martineau-120193074624@macmartineau.ccr.hydro.qc.ca> Followup-To: comp.dcom.sys.cisco Sender: news@ireq.hydro.qc.ca (Netnews Admin) Organization: Hydro Quebec References: <1993Jan6.184259.8546@ferrari.nmc.ed.ray.com> <93012.103138RHUNTER@ESOC.BITNET> Distribution: world,local Date: Tue, 12 Jan 1993 12:53:15 GMT Lines: 45