Re: Why do FIR filters always have odd tap counts?

#1359
From: Mark D. Grosen
Date: Fri, 07 Dec 1990 16:59
10 lines
981 bytes
Another reason to use odd-length FIR filters is that even-length
(symmetric) FIR filters always have a zero at omega = pi (ie, 1/2
the sampling rate).  This makes them unsuitable for use as highpass
filters, but possibly better for low or bandpass filters.
Mark D. Grosen		ARPA: grosen@amadeus.ucsb.edu
Signal Processing Lab / Communications Research Lab
ECE Dept.
University of California
Santa Barbara, CA  93106