RTS and CTS are *not* used for flow control at the application level. A DTE device sets RTS when it wishes to send something, which tells the DCE device (a modem) that it should do whatever is necessary to be ready to get some data. Then the modem raises CTS indicating that the device may send data. RS-232C is so misused by so many devices. There is a whole set of secondary channel signals defined for the DB-25 series of connectors which can be usurped, without screwing up current modem connections. I agree ^S/^Q was not a good choice, but the CTS/RTS or DSR/DTR pair are no better. -- Jon Mandrell (ihnp4!uw-beaver!tikal!amc!jon) Applied Microsystems Corp. "flames >& /dev/null" - me
Technical Details
Message-ID:
<260@amc.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!seismo!lll-crg!rutgers!sri-unix!hplabs!tektronix!uw-beaver!tikal!amc!jonReferences:
<8612011910.AA05601@icst-cmr.arpa.ARPA>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!seismo!lll-crg!rutgers!sri-unix!hplabs!tektronix!uw-beaver!tikal!amc!jon From: jon@amc.UUCP (Jon Mandrell) Newsgroups: comp.emacs Subject: Re: What's wrong with flow control? Message-ID: <260@amc.UUCP> Date: Tue, 2-Dec-86 22:24:14 EST Article-I.D.: amc.260 Posted: Tue Dec 2 22:24:14 1986 Date-Received: Sun, 7-Dec-86 02:16:36 EST References: <8612011910.AA05601@icst-cmr.arpa.ARPA> Reply-To: jon@amc.UUCP (Jon Mandrell) Organization: Applied Microsystems Corp.; Redmond, Wa. Lines: 16