Article View: comp.lang.postscript
Article #1507Re: 9600 bps bottleneck on Laserwriter Plus
From: Eric Fielding
Date: Sun, 14 Jan 1990 20:59
Date: Sun, 14 Jan 1990 20:59
10 lines
1054 bytes
1054 bytes
I successfully changed the baud rate on our LaserWriter Plus to 19200 baud (the fastest that our MicroVAX II terminal board seems to support), but I was unable to change the baud rate on our 'original' LaserWriter. It failed with a 'rangecheck' so I assume that it can't go faster than 9600 baud. The PS program that Amanda Walker posted did not include the 'exitserver' command that is needed to access the 'statusdict', which is probably a good idea as anyone who doesn't know about 'exitserver' should not be messing with the baud rate anyway. Thanks for posting this info! ++Eric Fielding
Technical Details
Message-ID:
<9543@batcomputer.tn.cornell.edu>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!uwm.edu!rpi!batcomputer!ericShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!uwm.edu!rpi!batcomputer!eric From: eric@batcomputer.tn.cornell.edu (Eric Fielding) Newsgroups: comp.lang.postscript Subject: Re: 9600 bps bottleneck on Laserwriter Plus Message-ID: <9543@batcomputer.tn.cornell.edu> Date: 14 Jan 90 20:59:29 GMT Reply-To: fielding@geology.tn.cornell.edu Distribution: na Organization: Department of Geological Sciences, Cornell University Lines: 10