Re: Manual feed with Adobe LaserJet II Cartridge

#4698
From: Woody Baker Eagle Signal
Date: Tue, 12 Feb 1991 05:26
15 lines
1014 bytes
In article <1991Feb10.000134.16805@trevan.uucp>, trevor@trevan.uucp writes:
> Please can someone tell me how I can get the printer to prompt for
> I get the FEED MANUAL prompt for a few seconds and then it goes away.


Set the default timeouts.
statusdict begin 0 exitserver
30 60 30 setdefaulttimeouts

sets the job timeout to 30 (the first param), the manual feed timout
to 60 and the serial communication timout to 30 seconds.  Experiment.
Normall this is 0 60 30, so if the manualfeed is to short, change it to
some larger number
Cheers
Woody