Would some kind soul please explain why the dot frequency values between
47.1405 and 60.6091 (inclusive) result in a frequency of 60.0 being used
internally? The angle for this to occur is 45 degrees.
I did a little test program that does a set screen and then turn right around
and do a currentscreen to print what the printer is using.
If the angle is 35 degrees, the test goes right through 60 without a problem.
This is using an increment to the frequency of .01 and starting at 59.0.
--
harvard\ att!nicmad\ spool.cs.wisc.edu!astroatc!vidiot!brown
Vidiot ucbvax!uwvax..........!astroatc!vidiot!brown
rutgers/ decvax!nicmad/ INTERNET:vidiot!brown%astroatc@spool.cs.wisc.edu
Technical Details
Message-ID:
<1453@vidiot.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!uwm.edu!uwvax!astroatc!vidiot!brownShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!news-server.csri.toronto.edu!cs.utexas.edu!wuarchive!uwm.edu!uwvax!astroatc!vidiot!brown From: brown@vidiot.UUCP (Vidiot) Newsgroups: comp.lang.postscript Subject: Apple LaserWriter IINT and setscreen Message-ID: <1453@vidiot.UUCP> Date: 7 Mar 91 06:47:35 GMT Reply-To: brown@vidiot.UUCP (Vidiot) Organization: Vidiot's Hangout Lines: 15