>>Thomson Consumer Electronic <bok@bok.net> wrote:

>>However, I can plug a Supra 28.8 in and change the init from at&f1 to
>>at&f2 (to keep hardware flow control) and no problems!

The difference between AT&F1 and AT&F2 has nothing to do with flow
control.  &F1 turns off the hardware DTR hangup option and makes the DCD
line always on.  &F2 turns on the hardware DTR hangup and makes DCD follow
the carrier.