Article View: comp.os.msdos.misc
Article #3050Re: Device driver for QIC-80 tape. Is there one?
From: Harvey G Shulman
Date: Mon, 23 Nov 1992 21:22
Date: Mon, 23 Nov 1992 21:22
41 lines
2640 bytes
2640 bytes
Some time ago I tried to get the same information, by posting to internet and Compuserve. Colorado Memory and other vendors all refused to provide software interfaces to their QIC-80 drives, claiming that they weren't meant for use as DOS devices. That was not satisfactory but its all they'd tell me. As a result I do know where to begin, but not much more. First you have to decide whether you really need a DOS device driver that treats the QIC-80 as though it were a disk drive. If that's true, give up, it can't be done in a satisfactory way. If instead you just want to write and read blocks of data in a sequential fashion and are willing to keep track of where in a file each record starts, etc, then you've got a chance. This is my situation, since all I wanted to do was store large blocks of data on the tape and associate a name and starting location with each, which is what the backup software that comes with the tape does. Second, you'd have to get the QIC-80 standard from whatever committee keeps track of these things. That's what CMS told me to do, and they can provide the name and address if pressed. Third, you'd have to write a device handler that deals with the drive controler and drive directly. There are some proprietary tricks involved that may or may not be part of QIC-80. For example the CMS drive shares the floppy cable with my B drive. The CMS software knows how to turn the tape drive on and the floppy off even though they're connected to the same interface. How? Clearly the vendors of QIC-80 drives, like Colorado Memory, have solved all of the above and could easily provide the device handler needed to perform a simple set of I/O functions. It is annoying and frustrating that they refuse to do so when asked. Hopefully one among them will see a competitive advantage in making such software available, but to date all I've contacted have the same attitude as CMS- "our equipment is only intended for DOS file backup, and is unusable for other purposes". Harvey Shulman Ohio State University
Technical Details
Message-ID:
<1992Nov23.212240.20362@magnus.acs.ohio-state.edu>Path:
arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!zaphod.mps.ohio-state.edu!magnus.acs.ohio-state.edu!hshulmanReferences:
<168A5B134.RKSHUKLA@SUVM.SYR.EDU>Show Full Headers
Complete Article Headers
Newsgroups: comp.os.msdos.misc Path: arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!zaphod.mps.ohio-state.edu!magnus.acs.ohio-state.edu!hshulman From: hshulman@magnus.acs.ohio-state.edu (Harvey G Shulman) Subject: Re: Device driver for QIC-80 tape. Is there one? Message-ID: <1992Nov23.212240.20362@magnus.acs.ohio-state.edu> Sender: news@magnus.acs.ohio-state.edu Nntp-Posting-Host: top.magnus.acs.ohio-state.edu Organization: The Ohio State University References: <168A5B134.RKSHUKLA@SUVM.SYR.EDU> Date: Mon, 23 Nov 1992 21:22:40 GMT Lines: 44