Article View: comp.os.msdos.programmer
Article #3781Load Overlay Function
From: Daniel Helander
Date: Wed, 14 Oct 1992 11:15
Date: Wed, 14 Oct 1992 11:15
27 lines
1237 bytes
1237 bytes
I need help using the MS-DOS load overlay function (int 21h, funtion 4b03).
The parameter block passed in es:bx looks like:
LOADOVERLAY STRUC
loStartSegment dw ?
loRelocationFactor dw ?
LOADOVERLAY ENDS
The loStartSegment is set to the place where the overlay is being read to.
The Microsoft Programmers Reference says that the relocation factor
"is typically the same as the loStartSegment value", but:
- What is this relocation factor?
The Microsoft Programmers Reference and Ralph Browns Interrupt List
tells nothing on how it can be used.
- Can it be set to another value in order to relocate the overlay
to another address than it was loaded to?
--
Daniel Helander danne@dynas.se
DynaSoft AB Phone: +46-8-726 85 60
Liljeholmsvagen 10
117 61 STOCKHOLM, SWEDEN Fax: +46-8-18 11 45
Technical Details
Message-ID:
<1992Oct14.111532.3601@dynas.se>Path:
arc1-ca.pugleaf.net!sparky!uunet!dtix!darwin.sura.net!jvnc.net!gmd.de!Germany.EU.net!mcsun!sunic!seunet!dynas!danneShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!dtix!darwin.sura.net!jvnc.net!gmd.de!Germany.EU.net!mcsun!sunic!seunet!dynas!danne From: danne@dynas.se (Daniel Helander) Newsgroups: comp.os.msdos.programmer Subject: Load Overlay Function Message-ID: <1992Oct14.111532.3601@dynas.se> Date: 14 Oct 92 11:15:32 GMT Sender: news@dynas.se (News Administrator) Organization: DynaSoft, Dynamic Software AB Lines: 27