From: Gary Heston
Date: Mon, 12 Aug 1996 00:00
29 lines
2003 bytes
In article <4ud5f1$55o@mtinsc01-mgt.ops.worldnet.att.net> bdhuskey@postoffice.worldnet.att.net (Brian Huskey) writes:
>I thought the default frame type for 3.x was 802.3 and that it was not
>until 4.x that the default became 802.2.
  [ ... ]

No, the change was made with 3.12. I remember the fuss that was caused
by that...numerous "I can't see my new server!" articles.

On my departmental net, which has two main segments (office and 
manufacturing areas), I run all three major frame types; on the link
to the Corporate network, which is done with a third card in my
central server (NW 3.11), we only use two frame types since it's all
supposed to be NW 4.1 and TCP/IP. We figured it'd be less hassle to
require all connections to the Corporate net use only the NW 4.x and
TCP/IP standard frames, thus minimizing the workload on the Corporate
support staff.

It doesn't hurt anything to bind both 802.2 and 802.3 to the NIC, and
can avoid a lot of headaches.

Gary


-- 
Gary Heston   SCI Systems, Inc.  gary@sci.com   Departmental net admin
   The Chairman of the Board and the CFO speak for SCI. I'm neither.
"All the observing stops, of course, when the observer hits the 
singularity at the center of the black hole." Dr. Robert L. Forward
Technical Details
Message-ID: <Dw02EG.F1B@scisysgw.sci.com>
Path: arc1-ca.pugleaf.net!unknown!not-for-mail
References: <4uasq3$s0m@caladan.restena.lu> <839539320snx@hwcces.demon.co.uk> <4ud5f1$55o@mtinsc01-mgt.ops.worldnet.att.net>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: fa939,cdfb6a439be90d1d
X-Google-Attributes: gidfa939,public
X-Google-Thread: fe659,cdfb6a439be90d1d
X-Google-Attributes: gidfe659,public
X-Google-Thread: f8bf7,cdfb6a439be90d1d
X-Google-Attributes: gidf8bf7,public
From: gary@scisysgw.sci.com (Gary Heston)
Subject: Re: Should new server be 802.2 or Ethernet II?
Date: 1996/08/12
Message-ID: <Dw02EG.F1B@scisysgw.sci.com>
X-Deja-AN: 173597708
references: <4uasq3$s0m@caladan.restena.lu> <839539320snx@hwcces.demon.co.uk> <4ud5f1$55o@mtinsc01-mgt.ops.worldnet.att.net>
organization: SCI Systems, Inc., Huntsville, Alabama
newsgroups: comp.os.netware.connectivity,bit.listserv.novell,comp.os.netware.misc