Article View: comp.os.netware.connectivity
Article #125Re: Should new server be 802.2 or Ethernet II?
From: Werner Steinmann
Date: Thu, 08 Aug 1996 00:00
Date: Thu, 08 Aug 1996 00:00
16 lines
1303 bytes
1303 bytes
Tom Kustner (kustner@emjay.com) wrote: : We are currently running 802.3 on a NetWare 3.12 server. We are : etc. Apart from other technical considerations you sometimes have to use certain frame types to work e.g. with TCP/IP (Ethernet_ii) or Appletalk (Ethernet_SNAP), or you might use boot ROMs with a fixed frame type, or you have a certain policy for routing/bridging etc. By the way, I have been using more than one frame type to overcome these sort of problems and obviously (and sometimes to my surprise) it worked. Werner Steinmann
Technical Details
Message-ID:
<4ucpr3$ork@news.tuwien.ac.at>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<32075b60.4395812@news.execpc.com>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: fe659,cdfb6a439be90d1d X-Google-Attributes: gidfe659,public X-Google-Thread: f8bf7,cdfb6a439be90d1d X-Google-Attributes: gidf8bf7,public X-Google-Thread: fa939,cdfb6a439be90d1d X-Google-Attributes: gidfa939,public From: nsteinma@ecx.tuwien.ac.at (Werner Steinmann) Subject: Re: Should new server be 802.2 or Ethernet II? Date: 1996/08/08 Message-ID: <4ucpr3$ork@news.tuwien.ac.at> X-Deja-AN: 172918391 references: <32075b60.4395812@news.execpc.com> followup-to: comp.os.netware.connectivity,bit.listserv.novell,comp.os.netware.misc organization: Vienna University of Technology, Austria newsgroups: comp.os.netware.connectivity,bit.listserv.novell,comp.os.netware.misc