Ray Todd Sevens wrote:
> Bottom line on 802.3 is that if you plan to use any other protocol    > besides ipx in your organization at anytime now or the future, don't  > use it.
 
Would you mind elaborating on this?
We run IPX on 802.3 and IP on Ethernet_II to Netware 3.12 and 4.1 boxes
with very good results...

-- 
Bill Ott			|	
wott@iserv.net			|	
dawgman1@ix.netcom.com		|
Technical Details
Message-ID: <322E0545.2A94@iserv.net>
Path: arc1-ca.pugleaf.net!unknown!not-for-mail
References: <32075b60.4395812@news.execpc.com> <4uasq3$s0m@caladan.restena.lu> <839539320snx@hwcces.demon.co.uk> <4umbbo$kj6@usenet10.interramp.com> <321279da.179763311@news.inlink.com> <4vqsht$8u0@lily.redrose.net> <raytodd.1051.0063488B@tima.com>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: fe659,cdfb6a439be90d1d
X-Google-Attributes: gidfe659,public
X-Google-Thread: fa939,cdfb6a439be90d1d
X-Google-Attributes: gidfa939,public
X-Google-Thread: f8bf7,cdfb6a439be90d1d
X-Google-Attributes: gidf8bf7,public
From: Bill <wott@iserv.net>
Subject: Re: Should new server be 802.2 or Ethernet II?
Date: 1996/09/04
Message-ID: <322E0545.2A94@iserv.net>
X-Deja-AN: 178532557
references: <32075b60.4395812@news.execpc.com> <4uasq3$s0m@caladan.restena.lu> <839539320snx@hwcces.demon.co.uk> <4umbbo$kj6@usenet10.interramp.com> <321279da.179763311@news.inlink.com> <4vqsht$8u0@lily.redrose.net> <raytodd.1051.0063488B@tima.com>
content-type: text/plain; charset=us-ascii
organization: Iserv.net, Grand Rapids, MI, USA
mime-version: 1.0
newsgroups: comp.os.netware.connectivity,bit.listserv.novell,comp.os.netware.misc
x-mailer: Mozilla 3.0 (Win95; I)