al919@cleveland.Freenet.Edu (Bruce Halco) writes:
>
> Some DOS software I'm writing involves async communications, and
> I figured using OS/2 to serve as 2 DOS machines would be more
> convenient than hooking up two physical computers. So I
> installed a 2-port serial card as COM3 and COM4 and looped the
> connectors back on the card. I modified CONFIG.SYS to correspond
> with the serial ports thusly:
>
> DEVICE=C:\OS2\COM.SYS (3,3E8,5) (4,2E8,9)
>
> But I _CAN NOT_ get reliable communications between the ports.
> What really drives me nuts is that I don't even get REPEATABLE
> results. One time I'll need COM_DIRECT_ACCESS on, the next day
> it needs to be off. COM_SELECT is restricted to the individual
> ports. IDLE_SENSITIVITY is set to 100 (disabled). I know the
> physical connection is OK because I can send individual bytes
> with DEBUG. Even when it _almost_ working, one port will send
> for a while, than pause until I hit a key in that session. Other
> times it sends nothing, or even refuses to start the session with
> an error about another session having access to that port (even
> if nothing else but the WPS is running). I've about run out of
> DOS session settings to modify, and I think I'm completely on the
> wrong track by now. What have I overlooked? BTW, the system is
> a 486/33, 16M RAM, SP installed over the GA release.
>
> Any and all suggestions will be welcomed.
I'm not sure, but I'm doing the same thing. I haven't been able to get it
going myself. Frist suggestion. Use external cables, don't try to jumper
the two on the card itself. Second suggestion. Get a NULL Modem cable,
or get a cable and null modem adapter.
The trick is to:
2 to 3
3 to 2
7 to 7
5,20 to 8 ? I think
There are several needed to be complete. Dont have that information off the
top of my head.. sorry.
Greg
.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.
. TCS Consulting Services P.O. Box 600008 St. Paul, MN 55106-0008 .
. ..!srcsip!tcscs!zeta ..!src.honeywell.com!tcscs!zeta .
.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.
Technical Details
Message-ID:
<ee4TwB2w165w@tcscs.UUCP>Path:
arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!uwm.edu!src.honeywell.com!tcscs!zetaReferences:
<1i89l3INNte@usenet.INS.CWRU.Edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!uwm.edu!src.honeywell.com!tcscs!zeta From: tcscs!zeta@src.honeywell.com (Gregory Youngblood) Newsgroups: comp.os.os2.misc Subject: Re: Make COM3 talk to COM4 Message-ID: <ee4TwB2w165w@tcscs.UUCP> Date: Sun, 03 Jan 93 22:55:01 CST References: <1i89l3INNte@usenet.INS.CWRU.Edu> Reply-To: zeta%tcscs@src.honeywell.com Organization: TCS Consulting Services Lines: 48