Re: Raid 7 Versus Earlier Raid 4

#1240
From: Thomas Weihrich
Date: Sun, 13 Dec 1992 13:01
33 lines
2352 bytes
Please keep in mind that only RAID Levels 0 through 5 are standardized.
Neither RAID 6 nor RAID 7 are standardized in any way. I have a Mylex
RAID at home which claims to be switchable to RAID 0,1,5,6 and 7.
They define RAID 6 as mixture of striping and mirroring, and RAID 7 as 
just a buch of disks (JBOD). While StorComps approach to RAID had a
couple of advantages, it is - to my mind - an implementation of a RAID
4, improved by large caches, thus trying to eliminate the bottle neck of
a single parity drive. Async transfers from the cache to the parity drive or
from the cache to the data drives have some disadvantages - for example
in a power fail situation. StorComp's RAID relies heavily on such async
transfers. You really need an uninterruptible power supply if you think
of using this disk array. At the moment I am evaluating RAID
implementations for a German unix magazine. I have had Storcomp's RAID
at home and think it performs nicely as long as there are enough hot
standby drives available. If a drive fails and if there is no hot
standby, performance will drop dramatically. There are a couple of
advantages the Storcomp RAID offers, but to my mind it is just a vendor
specific implementation of RAID 4 (it need not be bad just because it is
RAID 4).


Thomas Weihrich
-- 
------------------------------------------------------------------------------
Thomas Weihrich
Thomas.Weihrich@arbi.Informatik.Uni-Oldenburg.DE

Thomas.Weihrich@WWWA.ORG < this is a perfectly valid email address :)

#include <std_disclaimer.h>

	> We had joy, we had fun, we had PACMAN for the SUN ... <
-----------------------------------------------------------------------------
Technical Details
Message-ID: <1992Dec13.131309.9010@arbi.Informatik.Uni-Oldenburg.DE>
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!qt.cs.utexas.edu!yale.edu!ira.uka.de!math.fu-berlin.de!uniol!Thomas.Weihrich
References: <199212032043.AA20392@tuna.wang.com> <1992Dec8.141236.20204@seachg.uucp> <Bz34vE.Ay@queernet.org>

Show Full Headers
Complete Article Headers
Newsgroups: comp.periphs,comp.periphs.scsi,comp.arch.storage
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!cs.utexas.edu!qt.cs.utexas.edu!yale.edu!ira.uka.de!math.fu-berlin.de!uniol!Thomas.Weihrich
From: Thomas.Weihrich@arbi.informatik.uni-oldenburg.de (Thomas Weihrich)
Subject: Re: Raid 7 Versus Earlier Raid 4
Organization: University of Oldenburg, Germany
Date: Sun, 13 Dec 1992 13:01:47 GMT
Message-ID: <1992Dec13.131309.9010@arbi.Informatik.Uni-Oldenburg.DE>
References: <199212032043.AA20392@tuna.wang.com> <1992Dec8.141236.20204@seachg.uucp> <Bz34vE.Ay@queernet.org>
Sender: news@arbi.Informatik.Uni-Oldenburg.DE
Lines: 33