Article View: comp.periphs
Article #305Re: OMTI controller and HD
From: Keith Fellenstein
Date: Wed, 20 Sep 1989 20:39
Date: Wed, 20 Sep 1989 20:39
8 lines
883 bytes
883 bytes
There are no direct settings for the ST-251 in the 5520A booklet I found, but the settings for the ST-277R would appear to work, they list the same number of cylinders and heads. Try W1 off, W2 on, W3 on, and W4 off. You could also go through debug, g=c800:6 and answer no to the "use defaults" question, that would let you enter cylinders and heads directly. Keith
Technical Details
Message-ID:
<432@Intrepid.ece.ukans.edu>Path:
arc1-ca.pugleaf.net!utzoo!attcan!utgpu!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!uunet!deimos.cis.ksu.edu!Intrepid!kfellensReferences:
<1023@maestro.htsa.aha.nl>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!utgpu!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!uunet!deimos.cis.ksu.edu!Intrepid!kfellens From: kfellens@Intrepid.ece.ukans.edu (Keith Fellenstein) Newsgroups: comp.periphs Subject: Re: OMTI controller and HD Summary: Settings for ST-251 Keywords: HD, OMTI Message-ID: <432@Intrepid.ece.ukans.edu> Date: 20 Sep 89 20:39:58 GMT References: <1023@maestro.htsa.aha.nl> Reply-To: kfellens@Intrepid.UUCP (Keith Fellenstein) Organization: The University of Kansas Lines: 8