Article View: comp.periphs
Article #364Re: power requirements for 1/4" tape drives
From: Paul E. Berg
Date: Thu, 09 Nov 1989 23:54
Date: Thu, 09 Nov 1989 23:54
28 lines
1440 bytes
1440 bytes
>From: rsm@math.arizona.edu (Robert S. Maier)
>I just bought a quarter-inch Archive tape drive (model 2150S, ...
>... I don't have the manual for the tape drive yet, so I'm forced to
>ask the net: ... Will the tape drive actually use that much power?
Archive lists the power requirements for the 2060S and 2150S
(in their June 1988 revision product manual) as:
+12V +5
Tolerance (incl. max. +-10% +-5%
ripple of 200mV)
Standby Current 0.2 amps nom. 0.45 amps nom.
Operational Current 0.8 amps nom. 0.5 amps nom.
1.5 amps max. 0.7 amps max.
Tape Start Surge 2.5 amps max.
(up to 300msec.)
Power Dissapation 20 watts typ.
(operational) 35 watts max.
I think you should look for another enclosure. BTW, I've had no
trouble with a 2150S mounted inside my standard desktop enclosure.
Paul E. Berg | UUCP: ...uunet!zds-ux!paulb
Technical Details
Message-ID:
<10@zds-ux.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!shadooby!samsung!uunet!zds-ux!paulbReferences:
<RSM.89Nov8225829@obsidian.math.arizona.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!shadooby!samsung!uunet!zds-ux!paulb From: paulb@zds-ux.UUCP (Paul E. Berg) Newsgroups: comp.periphs Subject: Re: power requirements for 1/4" tape drives Summary: SCSI 2060S and 2150S power requirements (Archive Viper) Message-ID: <10@zds-ux.UUCP> Date: 9 Nov 89 23:54:31 GMT References: <RSM.89Nov8225829@obsidian.math.arizona.edu> Organization: Zenith Data Systems Lines: 28