🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.protocols.appletalk
Article #3613

Re: CAP6.0 pl126 with Sys7 and Sys6? (printer list problem)

#3613
From: Yoko Ozawa
Date: Tue, 17 Nov 1992 17:36
60 lines
3276 bytes
I love this group!  I came in this morning and found emailed responses
to my question already. (If only life was as easy -- sigh).  
Here's the summary for anyone else who may be interested:

The gist of my question was --

In article <1992Nov16.233222.10433@research.nj.nec.com> yoko@research.nj.nec.com (Yoko Ozawa) writes:
... 
YO> The CAP is running on a Sun and everything seemed fine [on System 7]
...
YO> Instead of giving us a beautifully sorted printer list, the System 6
YO> Chooser only provides a partial list (only 10 instead of ~20 printers)
YO> in random order.

***********
In response
***********

Christopher Davis <ckd@eff.org> wrote --

CKD> The System 6 Chooser has a rather, um, undersized buffer.  As you
CKD> have found out the hard way.  Live with it or upgrade...

Tom Ivar Helbekkmo <tih@barsoom.nhh.no> wrote --

TIH> That's the System 6 Chooser.  It works that way...  I doesn't sort
TIH> its lists, and it has only a small buffer for the service info, so
TIH> with many services and/or long service names, you won't see all of
TIH> them.  As a workaround, the user can open the Chooser,  scroll through
TIH> to the bottom of the list, and, if the wanted service is not found,
TIH> then wait.  New services seen will be added to the bottom of the
TIH> list, making it possible to scroll further down.  Repetition will
TIH> happen, but after a while (longer if you'e in a hurry, of course),
TIH> the needed service will show up.
TIH> 
TIH> Shorter service names will help, of course.
TIH> 
TIH> On the other hand, you might want to upgrade to 7...  :-)

I tried Tom's suggestion and the missing printers appeared (after a
few seconds each, and much repetition of the scroll-down-and-wait
procedure).  Goes to show you ... you can never be too impatient!  ;-)
Our System Administrator is playing with Zones now to see if this
would help to shorten the service list.

Obviously, as both Chris and Tom recommended, upgrading to System 7 is
the BEST way to eliminate the problem.  With the System 7 users
showing off the additional features, there IS a growing
"bite-the-bullet" sentiment in the user community.  That, and the fact
the 7.1 is already here, so one version below (7.0.1) doesn't seem as
bad -- can't be TOO backward, can we?  (Wish me luck!)

Thanks to you both!!!


-- 
:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
Yoko Ozawa             : NEC Research Institute, Inc.: yoko@research.nj.nec.com
Technical Administrator: 4 Independence Way          : 609 951-2511 (voice)
......................:.Princeton, NJ 08540.........:.609 951-2480 (fax ).....
Technical Details
Message-ID: <1992Nov17.173624.18666@research.nj.nec.com>
Path: arc1-ca.pugleaf.net!sparky!uunet!sun-barr!ames!elroy.jpl.nasa.gov!swrinde!zaphod.mps.ohio-state.edu!darwin.sura.net!jvnc.net!nj.nec.com!yoko
References: <Bxtuso.Au8@max.physics.sunysb.edu> <1992Nov16.233222.10433@research.nj.nec.com>

Show Full Headers
Complete Article Headers
Newsgroups: comp.protocols.appletalk
Path: arc1-ca.pugleaf.net!sparky!uunet!sun-barr!ames!elroy.jpl.nasa.gov!swrinde!zaphod.mps.ohio-state.edu!darwin.sura.net!jvnc.net!nj.nec.com!yoko
From: yoko@research.nj.nec.com (Yoko Ozawa)
Subject: Re: CAP6.0 pl126 with Sys7 and Sys6? (printer list problem)
Message-ID: <1992Nov17.173624.18666@research.nj.nec.com>
Originator: yoko@research.nj.nec.com
Sender: news@research.nj.nec.com
Organization: NEC Research Institute
References: <Bxtuso.Au8@max.physics.sunysb.edu> <1992Nov16.233222.10433@research.nj.nec.com>
Date: Tue, 17 Nov 92 17:36:24 GMT
Lines: 60