Re: question about SPDU

#576
From: John Freeborg
Date: Thu, 07 Jun 1990 19:52
21 lines
1232 bytes
   The concatenation rules specify that a GT SPDU (category 0) must ALWAYS
be prepended to a DT SPDU (category 2).  So often times you will see a
session PDU such as:

	01-00-01-00   followed by a bunch of data.  This is an "empty" 
GT SPDU concatenated with a DT SPDU (both LIs are 0).

You should never see a DT SPDU by itself since category 2 SPDUs must be 
concatenated with another SPDU.

Hope this helps,
   John


------------------------------------------------------------------------------
John W. Freeborg			Hewlett-Packard Company
jwf@hpcsos.col.hp.com			Colorado Telecommunications Division
jwf%hpctdkg@hplabs.hp.com		5070 Centennial Blvd.
'The opinions expressed are not		Colorado Springs, CO  80919
 necessarily those of my employer.'	(719) 531-4771
Technical Details
Message-ID: <5910005@hpctdia.HP.COM>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!mailrus!cs.utexas.edu!samsung!uakari.primate.wisc.edu!sdd.hp.com!hplabs!hpfcso!hpldola!hpctdlb!hpctdia!jwf
References: <9006051437.AA12834@ucbvax.Berkeley.EDU>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!mailrus!cs.utexas.edu!samsung!uakari.primate.wisc.edu!sdd.hp.com!hplabs!hpfcso!hpldola!hpctdlb!hpctdia!jwf
From: jwf@hpctdia.HP.COM (John Freeborg)
Newsgroups: comp.protocols.iso
Subject: Re: question about SPDU
Message-ID: <5910005@hpctdia.HP.COM>
Date: 7 Jun 90 19:52:31 GMT
References: <9006051437.AA12834@ucbvax.Berkeley.EDU>
Organization: Hewlett-Packard CTD, Colo. Spgs.
Lines: 21