🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.protocols.tcp-ip
Article #7957

Re: Sequence Numbers in TCP/IP

#7957
From: Mark Evans
Date: Fri, 22 Jan 1993 14:26
25 lines
1502 bytes
Andreas Fasbender (andreas@informatik.rwth-aachen.de) wrote:
: Can somebody answer a stupid question:
: 
: What is the reason for the difference in the lenght of the window-field
: (16)

The window is how much the other end is prepared to accept (65535 implies
infinite). (this is bigger than the maximum packet size on every network
I have ever seen)

: and the sequence-number-field (32 bit). Using 16-bit-numbers for sequencing
: and acknowledging could spare 4 byte in each packet.

Sequence measures how much has been sent.

Both of these are measured in octets (8 bit bytes), it is quite reasonable
to expect a TCP link to send more that 64K octets in one session.
: Hope this isn+t a faq.
: 
--

-------------------------------------------------------------------------
Mark Evans                                   |evansmp@uhura.aston.ac.uk
+(44) 21 429 9199  (Home)                    |evansmp@cs.aston.ac.uk
+(44) 21 359 6531 x4039 (Office)             |
Technical Details
Message-ID: <1993Jan22.142637.26110@aston.ac.uk>
Path: arc1-ca.pugleaf.net!sparky!uunet!pipex!warwick!sunserver1.aston.ac.uk!uhura!evansmp
References: <andreas-220193121931@i2pc5.informatik.rwth-aachen.de>

Show Full Headers
Complete Article Headers
Newsgroups: comp.protocols.tcp-ip
Path: arc1-ca.pugleaf.net!sparky!uunet!pipex!warwick!sunserver1.aston.ac.uk!uhura!evansmp
From: evansmp@uhura.aston.ac.uk (Mark Evans)
Subject: Re: Sequence Numbers in TCP/IP
Message-ID: <1993Jan22.142637.26110@aston.ac.uk>
Sender: usenet@aston.ac.uk (Usenet administrator)
Nntp-Posting-Host: uhura
Organization: Aston University
X-Newsreader: TIN [version 1.1 PL241235]
References: <andreas-220193121931@i2pc5.informatik.rwth-aachen.de>
Date: Fri, 22 Jan 1993 14:26:37 GMT
Lines: 25