🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.protocols.time.ntp
Article #635

NTP experiment - large drifts on unsynced systems

#635
From: paul
Date: Thu, 07 Mar 1991 15:56
13 lines
997 bytes
Running VMS 5.4-1 on both platforms with Multinet 2.2F (which contains
NTP), a VAXstation 3100 (called Lane) and a VAX 9000-210 (called
Kuhub) had been up for more than 8 days, and more than 1 day,
respectively.

As we made some hardware changes on our Internet router Internet
became unreachable for about 105 minutes.

Both Lane and Kuhub used exactly the same stratum 1 servers.

At the end of the 105 minutes of isolation the time difference between
Lane and Kuhub was approximately 2 seconds. That's approximately a
relative drift of 1 part in 3000. Why am I seeing such a large drift?