Keith and Clive, I have spent some time studying the Econet code and what it does is this. When StartTransmit is called the data from registers is checked and copied to an RMA block. Included in this block are the delay time (as passed in), the "start time" (initialised with the current time) and "finish time" (initialised with the current time plus ten seconds). The status is set to TxReady. This block is then stored as a part of a list Every centi-second the Econet code scans the list looking for TxCBs that are TxReady and have a start time <= the current time, when such a TxCB is found a pointer to it is passed to a standard routine for "starting" a transmission this routine first tries to get "line access" i.e. it sees if another station is transmitting. If there is access to the line the scout packet is sent. If the scout packet fails (NotListening) then the count value is decremented, if it becomes <= zero then the Not Listening status is recorded on the TxCB and that is that. If the count value has not yet reached zero then the delay time is added to the start time to make the new start time and ten seconds is added to that new start time to make the new finish time, and the status is set to TxReady. If there was no line access then the status is set to TxReady and none of the times or the count value are changed, however the current time is compared to the finish time and if the finish time is <= to the current time the TxCB is marked LineJammed and that is that. The PRM tries to explain this on pages 1339, 1340 and elaborates on page 1362. There isn't a queue as such there is a list (ordered by initial creation time) and this list contains all active transmissions i.e. from StartTransmit to AbandonTransmit. The processing of the list is as described above. As to the choice of count and delay times, this is a matter for the programmer to decide. The product of the count and delay values will give the approximate time before a 'terminal' status like NotListening or NetError will be returned (the exact time is (Count-1)*Delay). It is usual to set this to be between ten and forty seconds depending on the behaviour of the receiving machine. The actual delay value gives control over the granularity of noticing the state of the receiving station. For example if the count and delay are set to 2001 and 1 and the receiving station is not ready then the NotListening status will occur after 20 seconds, this would be that same as the other extreme values 2 and 2000. However in the former case within a centi-second of the receiving machine opening an RxCB the transmitter will succede, the latter case it will only 'notice' at the expiration of the 20 seconds. There is a drawback to always using a delay of one centi-second and that is other processes and other machines will find the world very hostile and difficult to use. Most Acorn protocols use a 10 centi-second delay value. This gives a nice balance to responsiveness and fairness without overloading the network or the machine. Note that if your receiver is known to have particular characteristics e.g. a server which always takes five seconds to process a request before accepting the next one then turning up the delay to, say, 100 centi-seconds would be the right thing to do. Hope that makes things a little clearer. Bruce. Any views expressed are my own and are not necessarily those _--_|\ of Acorn. Any factual information is given in good faith and / \ neither I, nor Acorn can accept liability for loss or damage \_.--._/ resulting from its use. v
Technical Details
Message-ID:
<19208@acorn.co.uk>Path:
arc1-ca.pugleaf.net!sparky!uunet!mcsun!uknet!acorn!bcockburnReferences:
<marlow.717842425@radon.sys.uea.ac.uk>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!mcsun!uknet!acorn!bcockburn From: bcockburn@acorn.co.uk (Bruce Cockburn) Newsgroups: comp.sys.acorn.tech Subject: Re: Econet timeouts Message-ID: <19208@acorn.co.uk> Date: 7 Oct 92 16:08:19 GMT References: <marlow.717842425@radon.sys.uea.ac.uk> Sender: daemon@acorn.co.uk Organization: Acorn Computers Ltd, Cambridge, England Lines: 64