In an earlier article ee91mds2@brunel.ac.uk (Mark D Smith) writes: >This sounds a rather odd problem, why should the RTC only stop counting when >it is being powered from the battery rather than the mains? The Arc reads the RTC when it powers up, but for speed it keeps a software copy of the clock in memory while it is turned on. So the clock could have `seized up' at a certain figure and this figure would be read at each power on, but counted forwards normally from then on under interrupt control. (What I think I mean is that *every* time the machine reboots it would start counting from the same point) Alun. -- +-------------------------------------------------------------------+ | Alun Jones, Computer Science Dept. | Email : auj@uk.ac.aber | | U.W. Aberystwyth, Wales | GW1URF (Packet coming soon!) | +--Hi, I'm a signature Virus :-) Copy me into your sig to join in.--+
Technical Details
Message-ID:
<1992Nov12.163520.4583@aber.ac.uk>Path:
arc1-ca.pugleaf.net!sparky!uunet!mcsun!uknet!gdt!aber!aujReferences:
<BxEEC3.2xM@brunel.ac.uk>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!mcsun!uknet!gdt!aber!auj From: auj@aber.ac.uk (Professor Coypu) Newsgroups: comp.sys.acorn.tech Subject: Re: real time and IIC Message-ID: <1992Nov12.163520.4583@aber.ac.uk> Date: 12 Nov 92 16:35:20 GMT References: <BxEEC3.2xM@brunel.ac.uk> Organization: Prifysgol Cymru (University of Wales) Aberystwyth Lines: 18