3_wire fix

#1571
From: Mark D. Henning
Date: Sun, 08 Oct 1989 21:49
75 lines
4213 bytes
Here is my promised posting of the solution to my 2 wire serial
problem.  I got two answers (one of them by several people).

The first answer would be very expensive and unprofitable.  This was
to get a pair of short-haul modems (about $300) at a fixed baud rate(
2400 I believe).  Anyway, This was not viable, because a network at
2400 would be unbearable.

The other solution I have posted below.  It is very good, however, I
am unsure whether or not it works, because I finally convinced
telecommunications to let me rewire the jacks (the 4 wire had been
run, but only 2 connected.)

Anyway, Thanks again to all who sent me the ideas.

^Mark,
^You actually have three wires available. The two in your room and
^ground.  The best option of all would be to use the phone ground.  If
^the phone system is hooked up in a standard way, one of the leads in
^the phone box will be ground.  You can use this ground for both the
^phone AND the RS-232 ground line since the potential of the dirt is
^the same in both cases (phone ground should be an actual ground -- if
^it's not, see the water pipe option).  This works less well with
^farther distances, but the phone ground is probably identical (within
^50 mV or so) in both rooms anyway.  To check if the phone ground is
^a real ground, measure the resistance between it and a water pipe
^(metal - metal pipes go into the dirt), though it actually doesn't
^matter as long as both phones are on the same ground circuit.  Another
^way to check the line would be as follows:
^
^            Room 1                 Room 2
^            ------                 ------
^
^       ---> A1 -------[    ]        [    ]------- A2 <----[VOM]
^       |       RS-232 [wall]        [wall] RS-232          | |
^       |--> B1 -------[    ]        [    ]------- B2 <------ |
^       |                                                     |
^       |                                                     |
^       ---> G1 -------[    ]        [    ]------- G2 <--------
^
^Tie all three wires together in 1 room.  Measure resistance between
^phone-net wire 1 (A2) and phone-net wire 2 (B2) -- it should be
^low (like 100, 200 ohms) -- if so, that means that the 2 wire setup
^is hooked up OK, no measure either of the phone-net lines in room 2
^(for ex. A2) to the ground in room 2 (G2).  If that is low too, it
^should all work fine.
^
^Note: Make SURE that the ground wire is used ONLY for the RS-232
^ground, NOT Tx or Rx -- hooking either of these to ground might
^fry the computer (the computer can't drive the dirt to +/- 12 VDC,
^and if it tries, it will probably fry).
^
^Other ground wire options include:
^    Since you are both in the same building (I infer from your post),
^    you can both hook the RS-232 grounds to the building ground to
^    complete the circuit.  If possible, you would use a water pipe,
^    then a building frame ground (assuming it is really grounded) --
^    many times window frames, door frames will be connected -- you
^    need to check this first.
^
^    Last choice would be the ground in a 3 prong outlet -- this is
^    dangerous if the building was not wired correctly.  Sometimes the
^    ground wire is wired to the neutral wire or even worse the hot
^    wire.  If so, this becomes dangerous.  Also, I don't like this
^    option since it puts a wire near 120 VAC.
^
^                                        Good Luck,
^                                        Rob Ginn
^                                        eraps1@nadc.arpa
-- 
------------------------------------------------------------
All opinions are my own, as are the spellings any deviation
from the norm is just an effect of late nights and early
mornings, with little sleep between.
Technical Details
Message-ID: <7225@thor.acc.stolaf.edu>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!wuarchive!gem.mps.ohio-state.edu!uakari.primate.wisc.edu!nic.MR.NET!thor.acc.stolaf.edu!henning

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!wuarchive!gem.mps.ohio-state.edu!uakari.primate.wisc.edu!nic.MR.NET!thor.acc.stolaf.edu!henning
From: henning@thor.acc.stolaf.edu (Mark D. Henning)
Newsgroups: comp.sys.amiga.tech
Subject: 3_wire fix
Keywords: ground to the room
Message-ID: <7225@thor.acc.stolaf.edu>
Date: 8 Oct 89 21:49:12 GMT
Organization: St. Olaf College; Northfield, MN
Lines: 75