> Hummmm... A friend of mine aquired a new 520FM last weekend. Very
> pretty and the tilt on the SM125 seemed like exactly what I need to
> keep my cat (furry variety as opposed to my antiquated modem) from
> sleeping atop it. Nevertheless, I too noticed that the monitor was
> very jittery. ..etc.
When I acquired my monochrome system in July 86, I did notice an
occasional jittery. Also a white ghost band (1/4 inch) would appear once
a while from left to right near the top of the screen. I returned the
monitor within a week, and the replacement I got (SM124) hasn't given
me any problem since (not even jittery).
With regards to skewed display, etc., one can quite easily open up
the monitor and make some adjustments. If you look at the deflection yoke,
it's held by a single screw located at the neck of the tube. Unscrew it
slightly, gently turn the yoke as approppriate, then tighten screw again.
Right by the screw are two deflection levers; these shift the image
horizontally. To enlarge the image, adjust the white plastic screws located
on the bottom circuit board of the monitor. (All these pertain only to
the SM124 since that's all I have)
Opening the monitor will VOID the warranty.
*** BE CAREFUL!! HIGH Voltage in vicinity ***
I hereby disclaim myself from any responsibility as a result of anyone
reading the above posting.
--
CSNET: lean@sbcs.csnet
ARPA: lean%suny-sb.csnet@csnet-relay.arpa
UUCP: {allegra, hocsd, philabs, ogcvax}!sbcs!lean
Technical Details
Message-ID:
<373@sbstaff2.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!water!watnot!watmath!clyde!rutgers!brl-adm!seismo!mcnc!philabs!sbcs!sbstaff2!leanReferences:
<4276@utah-cs.UUCP> <8447@watrose.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!utgpu!water!watnot!watmath!clyde!rutgers!brl-adm!seismo!mcnc!philabs!sbcs!sbstaff2!lean From: lean@sbstaff2.UUCP Newsgroups: comp.sys.atari.st Subject: Re: Jittery monitor Message-ID: <373@sbstaff2.UUCP> Date: Wed, 11-Feb-87 01:01:06 EST Article-I.D.: sbstaff2.373 Posted: Wed Feb 11 01:01:06 1987 Date-Received: Thu, 12-Feb-87 23:45:43 EST References: <4276@utah-cs.UUCP> <8447@watrose.UUCP> Organization: Computer Science Dept, SUNY@Stony Brook Lines: 28