Fried power cable

#1116
From: Michael Feeley
Date: Mon, 28 Dec 1992 13:28
29 lines
1478 bytes
        Last night the ribbon power cable that goes from the
    power supply to the motherboard on my Rainbow 100B started to
    melt (wire 6 from the right on the power supply end).  I have
    a replacement cable from a 100A and will attach it as soon as
    I can "air dust" the unit.
    
    Questions:
    
        1)  Are there any particular reasons for wire 6 frying?
    
        2)  Any way(s) to prevent a recurrence?
    
        3)  Any reason I shouldn't use the 100A cable (it looks
    OK)?
    
        4)  One solution that comes to mind is to get a monitor
    that doesn't draw on the Rainbow power supply.  I have a
    Rainbow RGB cable.  Would anyone know of reasonable
    (new/used) monitor brands (in addition to the DEC VR-241)
    that function with a Rainbow?
    
    Thanks in advance.
    
    Mike
    
---
 . SPEED 1.3f #1089 . Logjam -- Some kind of high fiber jelly.
                                                                                                                     
Technical Details
Message-ID: <43.1188.uupcb@satalink.com>
Path: arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!yale.edu!jvnc.net!netnews.upenn.edu!dsinc!satalink!michael.feeley

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!spool.mu.edu!yale.edu!jvnc.net!netnews.upenn.edu!dsinc!satalink!michael.feeley
From: michael.feeley@satalink.com (Michael Feeley)
Newsgroups: comp.sys.dec.micro
Subject: Fried power cable
Message-ID: <43.1188.uupcb@satalink.com>
Date: 28 Dec 92 13:28:00 GMT
Reply-To: michael.feeley@satalink.com (Michael Feeley)
Organization: Datamax/Satalink Connection * Ivyland, PA (215) 443-9434
Lines: 29