Does anyone have any hard data on a fix for the infamous VR260 plague (other than buying a better monitor, that is)? For anyone not familiar these tubes have a tendency to blow out deflection boards at irregular intervals -- you know you have one when the monitor won't fire and all you get is a noise pulse from the rear and a slowly blinking power LED. I had heard that the culprit was the IRF622 N-style regulator on the board. I tried replacing one, though, with no effect, but I'm REALLY TIRED of having to call DEC in to replace the boards. Anyone know of a good fix? Thanks, Dick Joltes joltes@husc9.harvard.edu Mgr. of Hardware & Facilities Harvard University Science Center
Technical Details
Message-ID:
<4563@husc6.harvard.edu>Path:
arc1-ca.pugleaf.net!utzoo!attcan!uunet!husc6!husc9!joltesShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!husc6!husc9!joltes From: joltes@husc9.harvard.edu (Richard Joltes) Newsgroups: comp.sys.dec Subject: VR260 Plague Message-ID: <4563@husc6.harvard.edu> Date: 31 Oct 90 16:28:48 GMT Sender: news@husc6.harvard.edu Reply-To: joltes@husc9.harvard.edu (Richard Joltes) Organization: Harvard University Science Center Cambridge, MA Lines: 17