🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.dec
Article #2397

Re: VR260 Plague

#2397
From: Jim Durham
Date: Fri, 09 Nov 1990 20:09
23 lines
1517 bytes
In article <4563@husc6.harvard.edu> joltes@husc9.harvard.edu (Richard Joltes) writes:
>Does anyone have any hard data on a fix for the infamous VR260 plague (other
>than buying a better monitor, that is)?  For anyone not familiar these tubes
>have a tendency to blow out deflection boards at irregular intervals -- you
(stuff deleted)>
>I had heard that the culprit was the IRF622 N-style regulator on the board.  I
>tried replacing one, though, with no effect, but I'm REALLY TIRED of having to
>call DEC in to replace the boards.
>
The culprit seems to be the flyback transformer.

>Anyone know of a good fix?

Apparently DEC has a new version of the board. I thought this fixed the
problem, but from what you say, maybe not.

I was wondering if a fan would help. VR-260s seem to run really warm.
If you notice, the source resistors for the Mosfets burn the board
and there's a lot of heat coming out the vents. This would cool the
flyback and the Mosfets.>

-Good Luck
Jim Durham   (jcd@cs.pitt.edu | durham@w2xo.pgh.pa.us )
Technical Details
Message-ID: <9116@pitt.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!swrinde!zaphod.mps.ohio-state.edu!ub!uhura.cc.rochester.edu!rochester!pt.cs.cmu.edu!dsl.pitt.edu!pitt!jcd
References: <4563@husc6.harvard.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!swrinde!zaphod.mps.ohio-state.edu!ub!uhura.cc.rochester.edu!rochester!pt.cs.cmu.edu!dsl.pitt.edu!pitt!jcd
From: jcd@pitt.UUCP (Jim Durham)
Newsgroups: comp.sys.dec
Subject: Re: VR260 Plague
Message-ID: <9116@pitt.UUCP>
Date: 9 Nov 90 20:09:13 GMT
References: <4563@husc6.harvard.edu>
Reply-To: jcd@vax.cs.pitt.edu.UUCP (Jim Durham)
Organization: Univ. of Pittsburgh Computer Science
Lines: 23