🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.dec
Article #2928

Re: Vax750 PROBLEMS!!

#2928
From: j_prigot
Date: Wed, 26 Dec 1990 14:20
19 lines
1463 bytes
In article <1990Dec19.171315.903@spcvxb.spc.edu>, terry@spcvxb.spc.edu (Terry Kennedy, Operations Mgr) writes:
> In article <1990Dec18.170238.6551@uunet!konkord>, jar@konkord.uucp (John Roberts) writes:
>> 	ANY HELP would be great! I've been working on this
>> 	problem for 2 weeks now, and NOTHING!!! ARG!!!
> 
>   If you inherited this VAX from somewhere where it was on a DEC Field Service
> contract, FS has removed the Remote Diagnostic Module from slot 6 (I think),
> leaving the TU58 and the console disconnected. Look at the cover on the back-
> plane - it should have a sticker showing where to move the connectors to in
> order to work w/o the RDM installed. It also shows the baud rate select jum-
> pers for the console port.
> 

And in case it doesn't, my "VAX Maintenance Handbook (VAX-11/750)" says to
move the following cables from the right side of slot 6 to the left side: Front
panel cable (row A), TU58 cable (row B), console cable (row C).

-- 
Jonathan M. Prigot      j_prigot@wrglex or ...!drilex!wrglex!j_prigot
Technical Details
Message-ID: <111.27786b76@wrglex.uucp>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!apple!bbn.com!drilex!wrglex!j_prigot
References: <1990Dec18.170238.6551@uunet!konkord> <1990Dec19.171315.903@spcvxb.spc.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!apple!bbn.com!drilex!wrglex!j_prigot
From: j_prigot@wrglex.uucp
Newsgroups: comp.sys.dec
Subject: Re: Vax750 PROBLEMS!!
Message-ID: <111.27786b76@wrglex.uucp>
Date: 26 Dec 90 14:20:54 GMT
References: <1990Dec18.170238.6551@uunet!konkord> <1990Dec19.171315.903@spcvxb.spc.edu>
Organization: W.R. Grace & Co., Lexington, MA
Lines: 19